Measures reported by CisASRPwStatTest

A Field-Replaceable Unit (FRU) is circuit board or part that can be quickly and easily removed and replaced in this router without having to send the entire product or system to repair facility. The FRUs can be Fan tray, Physical Interface Card or Redundant Power Supply. This test helps the administrators to monitor the admin and operational status of these FRUs.

Outputs of the test : One set of results for each FRU in the target Cisco ASR Router.

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
adminStatus Indicates the admin status of this FRU.   The values reported by this measure and their numeric equivalents are available in the table below:

Measure Value Numeric Value
On 1
Off 2
Inline auto 3
Inline on 4
Power cycle 5


Note:

By default, this measure reports the above-mentioned Measure Values to indicate the admin status of this FRU in the target Cisco ASR router. In the graph of this measure however, the same is represented using the corresponding numeric equivalents only.
operStatus Indicates the operational status of this FRU.   The values reported by this measure and their numeric equivalents are available in the table below:

Measure Value Numeric Value
Off envOther 1
On 2
Off admin 3
Off denied 4
Off envPower 5
Off envTemp 6
Off envFan 7
Failed 8
On but fan fail 9
Off cooling 10
Off connector rating 11
On but inline power fail 12


Note:

By default, this measure reports the above-mentioned Measure Values listed in the table above to indicate the operational status of this FRU in the target Cisco ASR router. In the graph of this measure however, the same is represented using the corresponding numeric equivalents only.