eG Monitoring
 

Measures reported by PKTSSensorStTest

Sensors are of three types namely Fan sensor, Voltage sensor and Temperature sensor. This test monitors each of the voltage sensors and temperature sensors on the PacketShaper Load Balancer S-Series device, and reports the current status of those sensors. By carefully analyzing the status, administrators can figure out the exact hardware component that has failed / malfunctioning due to voltage and temperature fluctuations.

Outputs of the test : One set of the results for the target PacketShaper Load Balancer S-Series device that is being monitored

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
voltSensorStatus Indicates the current status of the voltage sensors in the load balancer.   The table below indicates the values that this measure can report and their corresponding numeric equivalents:

Measure Value Numeric Value
Voltage Ok 0
Bad voltage on CPU 1
Bad voltage on 1.1v input 2
Bad voltage on CPU, 1.1v input 3
Bad voltage on 12v input 4
Bad voltage on CPU, 12v input 5
Bad voltage on 12v, 1.1v input 6
Bad voltage on CPU, 12v, 1.1v input 7
Bad voltage on 3v input 8
Bad voltage on CPU, 3v input 9
Bad voltage on 3v, 1.1v input 10
Bad voltage on CPU, 3v, 1.1v input 11
Bad voltage on 3v, 12v input 12
Bad voltage on CPU, 3v, 12v input 13
Bad voltage on 3v, 12v, 1.1v input 14
Bad voltage on CPU, 3v, 12v, 1.1v input 15
Bad voltage on 5v input 16
Bad voltage on CPU,5v input 17
Bad voltage on 5v, 1.1v input 18
Bad voltage on CPU, 5v, 1.1v input 19
Bad voltage on 5v, 12v input 20
Bad voltage on CPU, 5v, 12v input 21
Bad voltage on 5v, 12v, 1.1v input 22
Bad voltage on CPU, 5v, 12v, 1.1v input 23
Bad voltage on 5v, 3v input 24
Bad voltage on CPU, 5v, 3v input 25
Bad voltage on 5v, 3v, 1.1v input 26
Bad voltage on CPU, 5v, 1.1v input 27
Bad voltage on 5v, 3v, 12v input 28
Bad voltage on CPU, 5v, 3v, 12v input 29
Bad voltage on 5v, 3v, 12v, 1.1v input 30
Bad voltage on CPU,5v, 3v, 12v, 1.1v input 31

Note:

By default, this measure reports the above-mentioned Measure Values while indicating the current status of the voltage sensor. However, in the graph of this measure, the status of the voltage sensor will be represented using the corresponding numeric equivalents only - i.e., 0 to 31.

tempSensorStatus Indicates the current status of the temperature sensors mounted on the hardware components of the load balancer.   The table below indicates the values that this measure can report and their corresponding numeric equivalents:

Measure Value Numeric Value
Temperature Ok 0
Bad temp on CPU sensor 1
Bad temp on RAM 2
Bad temp on RAM and CPU 3
Bad temp on Motherboard 4
Bad temp on Motherboard, CPU 5
Bad temp on Motherboard, RAM 6
Bad temp on Motherboard, RAM, CPU 7
Bad temp on Powersupply unit 8
Bad temp on Powersupply unit, CPU 9
Bad temp on Powersupply unit, RAM 10
Bad temp on Powersupply unit, CPU, RAM 11
Bad temp on Powersupply unit, Motherboard 12
Bad temp on PSU, Motherboard, CPU 13
Bad temp on PSU, Motherboard, RAM 14
Bad temp on PSU, Motherboard, CPU, RAM 15

Note:

By default, this measure reports the above-mentioned Measure Values while indicating the current status of the temperature sensors. However, in the graph of this measure, the status of the temperature sensors will be represented using the corresponding numeric equivalents only-i.e., 0 to 15.