Measures reported by UnityIOTest
This test auto-discovers the I/O modules on the target storage system and for each I/O module, reports the current health. Using this test, administrators may be alerted to I/O module that failed/degraded and replace those I/O module before irreparable damage occurs to the target storage system.
Outputs of the test : One set of results for each I/O module on the target storage system being monitored.
The measures made by this test are as follows:
| Measurement |
Description |
Measurement Unit |
Interpretation |
| healthStatus |
Indicates the current health of this I/O module. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure value |
Numeric Value |
| Normal |
0 |
| Attention |
1 |
| Unknown |
2 |
| Degraded/Warning |
3 |
| Minor failure |
4 |
| Major failure |
5 |
| Critical failure |
6 |
| Non-recoverable error |
7 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the current health of this I/O module. The graph of this measure however is represented using the numeric equivalents only - 0 to 7.
The detailed diagnosis of this measure lists the ID, slot, health of the I/O module, model and serial number of the I/O module.
|
|