Measures reported by HBladeFanModuleTest
The cooling of the Hitachi Compute Blade is governed by six efficient, variable-speed, redundant fan modules. Each fan module includes three fans to tolerate fan failures within a module; an entire module can fail while the other fan modules continue to support the cooling requirements of the chassis. If the fan modules fail frequently, then the cooling of the hardware components of the Hitachi Compute Blade may fluctuate leading to abnormal rise in temperature. This may sometimes cause a permanent damage of the Hitachi Compute Blade. To avoid such critical damage, administrators should constantly monitor the health of the fan modules. The HBladeFanModuleTest test comes in handy to those administrators who would like to monitor the fan modules round the clock!
This test reports the current health of each fan module in the chassis, thus turning the spotlight on those modules that have failed. In addition, the test also checks the status of the power supply to each fan module and also alerts administrators to the redundancy status of each fan module.
The measures made by this test are as follows:
| Measurement |
Description |
Measurement Unit |
Interpretation |
| Health_Status |
Indicates the current health of this fan module. |
|
The values that this measure can report and the numeric values they indicate have been listed in the table below:
| State |
Numeric Value |
| Normal |
1 |
| Failed |
2 |
| Unknown |
0 |
Note:
By default, this measure can report the Measure Values mentioned above while indicating the current health of each fan module. However, the graph of this measure is indicated using the numeric equivalents.
|
| Power_Status |
Indicates the current power status of this fan module. |
|
The values that this measure can report and the numeric values they indicate have been listed in the table below:
| Measure Value |
Numeric Value |
| PowerOff |
1 |
| Standby |
2 |
| PowerOn |
3 |
| Unknown |
4 |
| PowerOn Executing |
5 |
| PowerOff Executing |
6 |
Note:
By default, this measure can report the Measure Values mentioned above while indicating the power status of each fan module. However, the graph of this measure is indicated using the numeric equivalents.
|
| Redundancy_status |
Indicates the current redundancy status of this fan module. |
|
The values that this measure can report and the numeric values they indicate have been listed in the table below:
| State |
Numeric Value |
| Redundancy |
1 |
| Non Redundancy |
2 |
| Unknown |
3 |
Note:
By default, this measure can report the Measure Values mentioned above while indicating the current redundancy status of each fan module. However, the graph of this measure is indicated using the numeric equivalents.
|
|