| Measurement |
Description |
Measurement Unit |
Interpretation |
| connState |
Indicates the connection state of this initiator to the XtremIO storage array via atleast one target port. |
|
The values reported by this measure and their numeric equivalents are available in the table below:
| Measure Value |
Numeric Value |
| Connected |
0 |
| Disconnected |
1 |
| Unknown |
1 |
Note:
This measure reports the Measure Values listed in the table above to indicate the connection state of this initiator. However, in the graph, this measure is indicated using the Numeric Values listed in the above table. |
| bandwidth |
Indicates the amount of data utilized for performing I/O operations per second through this initiator. |
MB/Sec |
|
| readBandwidth |
Indicates the amount of data utilized for performing read I/O operations per second through this initiator. |
MB/Sec |
|
| writeBandwidth |
Indicates the amount of data utilized for performing write I/O operations per second through this initiator. |
MB/Sec |
|
| iops |
Indicates the rate at which I/O operations were performed through this initiator during the last measurement period. |
IOPS |
Compare the value of this measure across the initiators to know which initiator handled the maximum number of I/O operations and which handled the least. If the gap between the two is very high, then it indicates serious irregularities in I/O operations across the initiators. |
| readIOPS |
Indicates the number of read operations performed through this initiator per second. |
IOPS |
|
| writeIOPS |
Indicates the number of the write operations performed through this initiator per second. |
IOPS |
|
| readLatency |
Indicates the time taken to perform read operations through this initiator. |
msec |
A low value is desired for this measure. A high value indicates that the read and write operations take too long to execute which directly affects the performance of the Xtremio Storage Array. |
| writeLatency |
Indicates the time taken to perform write operations through this initiator. |
msec |
| avgLatency |
Indicates the average time taken to perform I/O operations through this initiator. |
msec |
|
| reads |
Indicates the rate at which the read operations were performed through this initiator during the last measurement period. |
Reads/sec |
Compare the value of this measure across initiators to know which initiator handled the maximum number of read requests and which handled the least. |
| writes |
Indicates the rate at which the write operations were performed through this initiator during the last measurement period. |
Writes/Sec |
Ideally, the value of this measure should be high. A steady dip in this measure value could indicate a potential writing bottleneck. By comparing the value of this measure across the initiators, you can quickly identify the initiator which is the slowest in processing write requests. |
| dataReads |
Indicates the rate at which data was read through this initiator during the last measurement period. |
MB/Sec |
Compare the values of these measures across the initiators to identify the slowest initiator in terms of servicing read and write requests (respectively). |
| dataWritten |
Indicates the rate at which data was written through this initiator during the last measurement period. |
MB/Sec |
| avgReadSize |
Indicates the amount of data read through this initiator per I/O operation during the last measurement period. |
MB/Op |
Compare the values of these measures across the initiators to identify the slowest initiator in terms of servicing read and write requests (respectively). |
| avgWriteSize |
Indicates the amount of data written through this initiator per I/O operation during the last measurement period. |
MB/Op |