eG Monitoring
 

Measures reported by NetCluSysStatTest

This test monitors the NetApp Cluster's support environment - which includes its hardware, the fans, the power supply units, and the battery - and promptly alerts you to current/potential issues in the health of this environment. These issues can range from abnormal hardware temperature to batteries fast-approaching their end-of-life and more!

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
Cpu_busy Indicates the percentage of time for which the CPU time was busy performing system-level processing during the last measurement period. Percent A high value indicates that the storage system is utilizing CPU resources excessively. A consistent increase in this value could indicate a potential CPU contention on the storage system.
Temperature Indicates whether/not the hardware is currently operating outside its recommended temperature range.   This measure reports a value Yes if the hardware temperature is operating outside the recommended temperature range and No if otherwise.

The numeric values corresponding to the above-mentioned measure values are as follows:

Measure Value Numeric Value
No 1
Yes 2

Note:

By default, this measure reports the above-mentioned Measure Values while indicating whether the hardware is operating within the recommended temperature range or not. However, the graph of this measure will be represented using the corresponding numeric equivalents i.e., 1 or 2 only.

Fan_failed Indicates the number of fans that failed in the NetApp Cluster. Number The detailed diagnosis capability, if enabled for this test, will list the fans that failed and the reason for their failure.
Failed_power_supply Indicates the number of power supply units that failed in the NetApp Cluster. Number The detailed diagnosis capability, if enabled for this test, will list the power supply units that have failed and the reason for their failure.
Battery_status Indicates the current status of the NVRAM battery.   The values reported by this measure and their numeric equivalents are available in the table below:

Measure Value Numeric Value
Ok 1
Partially discharged 2
Fully discharged 3
Not present 4
Near end of life 5
At end of life 6
Unknown 7
Over charged 8
Fully charged 9

Note:

This measure reports the Measure Values listed in the table above to indicate the current battery status. However, in the graph of this measure, the same will be represented using only the Numeric Values listed in the above table.