eG Monitoring
 

Measures reported by IbmStorwizeEncSlotTest

This test reports the status of the ports that are present on each of the Enclosure slot provided on the IBM Storwize v7000 storage device. Further, this test reveals the information on whether a drive is inserted into this slot and if so, reports the ID of the inserted drive.

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
port1_status Indicates the current status of port 1 on this Enclosure slot.

“This measure is not applicable for the NVMe enabled drives.”
  The values that this measure can report and their corresponding states are mentioned in the table below:

Measure Value Numeric Value Description
offline 0 The port is offline
online 1 The port is online
excluded_by_drive 2 The drive excluded the port
excluded_by_enclosure 3 The enclosure excluded the port
excluded_by_system 4 The system excluded the port
excluded_by_cluster 5 The cluster excluded the port
others 6 Other reasons

Note:

By default, this measure reports the above-mentioned states while indicating the status of the port 1. However, the graph of this measure will be represented using the corresponding numeric equivalents of the Measure Values as mentioned in the table above.
port2_status Indicates the current status of port 2 of this Enclosure slot.

“This measure is not applicable for the NVMe enabled drives.”
  The values that this measure can report and their corresponding states are mentioned in the table below:

Measure Value Numeric Value Description
offline 0 The port is offline
online 1 The port is online
excluded_by_drive 2 The drive excluded the port
excluded_by_enclosure 3 The enclosure excluded the port
excluded_by_system 4 The system excluded the port
excluded_by_cluster 5 The cluster excluded the port
others 6 Other reasons

Note:

By default, this measure reports the above-mentioned Measure Values while indicating the status of the port 2. However, the graph of this measure will be represented using the corresponding numeric equivalents of the Measure Values as mentioned in the table above.
drive_present Indicates whether/not a drive is inserted into this Enclosure slot.   This measure indicates a value Yes if the drive is present and a value No if otherwise.

The numeric equivalents of these values are mentioned in the table below:

Measure Value Numeric Value
No 0
Yes 1
Note:

By default, this measure reports the above-mentioned Measure Values while indicating the presence of the drive in this Enclosure slot. However, the graph of this measure will be represented using the corresponding numeric equivalents of the Measure Values as mentioned in the table above.
drive_id Indicates the ID of the drive that is currently inserted into this Enclosure slot. Number