Measures reported by DellHwArrCtlTest
This test reports the current operational and error state of each of the array controllers on Dell hardware, and also reports the current configuration of each array controller, such as its type, cache size, and memory size.
The measures
made by this test are as
follows:
| Measurement |
Description |
Measurement Unit |
Interpretation |
| Type |
Indicates the type of this array controller. |
|
The values this can measure report and their numeric equivalents are available in the table below:
| Measure Value |
Numeric Value |
| SCSI |
1 |
| PV660F |
2 |
| PV662F |
3 |
| IDE (Integrated / Intelligent Drive Electronics) |
4 |
| SATA (Serial Advanced Technology Attachment) |
5 |
| SAS (Serial Attached SCSI) |
6 |
Note:
This measure reports the Measure Values listed in the table above to indicate the array controller type. However, in the graph of this measure, the type is indicated using only the Numeric Values listed in the above table. |
| State |
Indicates the current operational state of this array controller. |
|
The values this measure can report and their numeric equivalents are available in the table below:
| Measure Value |
Numeric Value |
| Unknown |
0 |
| Ready |
1 |
| Failed |
2 |
| Online |
3 |
| Offline |
4 |
| Degraded |
6 |
Note:
This measure reports the Measure Values listed in the table above to indicate the current state of an array controller. However, in the graph of this measure, the operational state is indicated using only the Numeric Values listed in the above table. |
| RebuildRate |
Indicates the percentage of compute cycles dedicated to rebuilding failed array disks in this array controller. |
Percent |
During a rebuild, the complete contents of an array disk are reconstructed. The rebuild rate, configurable between 0% and 100%, represents the percentage of the system resources dedicated to rebuilding failed array disks. At 0%, the rebuild will have the lowest priority for the controller, will take the most time to complete, and will be the setting with the least impact to system performance. A rebuild rate of 0% does not mean that the rebuild is stopped or paused.
At 100%, the rebuild will be at the highest priority for the controller, will minimize the rebuild time, and will be the setting with the most impact to system performance. |
| CacheSizeinMB |
Indicates the current amount of memory in the cache of this array controller. |
MB |
|
| PhysicalDeviceCount |
Indicates the number of physical devices on this controller channel including both disks and the controller. |
Number |
|
| LogicalDeviceCount |
Indicates the number of virtual disks on this controller. |
Number |
|
| MemorySizeinMB |
Indicates the size of this controller's memory. |
MB |
|
| SeverityState |
Indicates the status of the controller itself without the Propagation of any contained component status. |
|
The values this measure can report and their numeric equivalents are available in the table below:
| Measure Value |
Numeric Value |
| Other |
1 |
| Unknown |
2 |
| OK |
3 |
| Non-critical |
4 |
| Critical |
5 |
| Non-recoverable |
6 |
Note:
This measure reports the Measure Values listed in the table above to indicate the current status of an array controller. However, in the graph of this measure, the operational state is indicated using only the Numeric Values listed in the above table. |
|