eG Monitoring
 

Measures reported by HPEvaEncFCPortTest

This test indicates the current state and overall health of each Fibre Channel port on the EVA storage array.

 The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
Operational_state Indicates the current operational mode of this FC port.   The table below displays the States that can be reported by this measure, and their numeric equivalents:

State Value
failed or bad 0
good, attention, or normal 1
unknown, not availabe, notinstalled, not_present, unsupported, etc. 2

Note:

By default, this measure reports one of the States listed in the table above. The graph of this measure however will represent the operational state using the numeric equivalents - ‘0’ to ‘2’.

Failure_predict Indicates whether failure of this FC port has been predicted.   The table below displays the Responses that can be reported by this measure, and their numeric equivalents:

Response Value
yes 0
no 1
Unknown, etc. 2

Note:

By default, this measure reports one of the Responses listed in the table above. The graph of this measure however will represent the failure predicted using the numeric equivalents - ‘0’ to ‘2’.

Output_link Indicates the current state of the output link of this FC port.   The table below displays the States that can be reported by this measure, and their numeric equivalents:

State Value
bad, failed, inactive 0
good, normal, active 1
unknown, etc. 2

Note:

By default, this measure reports one of the States listed in the table above. The graph of this measure however will represent the output link state using the numeric equivalents - ‘0’ to ‘2’.

Input_link Indicates the current state of the input link of this FC port.   The table below displays the States that can be reported by this measure, and their numeric equivalents:

State Value
bad, failed, inactive 0
good, normal, active 1
unknown, etc. 2

Note:

By default, this measure reports one of the States listed in the table above. The graph of this measure however will represent the input link state using the numeric equivalents - ‘0’ to ‘2’.

FC_port_state Indicates the current status of the FC port.   The table below displays the States that can be reported by this measure, and their numeric equivalents:

State Value
disabled, bad, invalid 0
enabled, good, valid 1
unknown, etc. 2

Note:

By default, this measure reports one of the States listed in the table above. The graph of this measure however will represent the FC port state using the numeric equivalents - ‘0’ to ‘2’.