Measures reported by CpqEnclTempTest
This test auto-discovers the temperature sensors in each blade enclosure, and reports the current temperature reading and current state of each sensor.
The measures
made by this test are as
follows:
| Measurement |
Description |
Measurement
Unit |
Interpretation |
| Current_temp |
Indicates the current temperature reading for this sensor
|
Celsius |
By comparing the value of this measure across sensors, you can accurately determine which sensor is currently experiencing abnormally high temperatures. The value -1 for this measure indicates that the eG agent could not determine the temperature of the sensor.
|
| Temp_condition |
Indicates the current condition of this sensor |
Number |
The table below lists the values that this measure can report and the states they indicate:
| Value |
State |
Description |
| 1 |
Other |
Temperature could not be detected |
| 2 |
OK |
The temperature sensor is within the normal operating range |
| 3 |
Degraded |
The temperature sensor is outside of the normal operating range |
| 4 |
Failed |
The temperature sensor detects a condition that could possibly damage the system. The system will automatically shutdown if the failed condition results. |
|
|