eG Monitoring
 

Measures reported by ClariionDAETest

This test reveals the status of the hardware components of the disk array enclosure, such as, the fans, the power supply units, and the LCC. Potential hardware failures in the enclosure can be proactively determined with the help of this test.

 The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
Fan_A_state This measure indicates the current state of Fan A.   If the fan A is unavailable, then this measure will return the value Not Present. On the other hand, if fan A is available, then the value of this measure will be Present.

The numeric values that correspond to each of the states discussed above are as follows:

Value State
1 Present
0 Not Present

Note:

By default, this measure reports the values Present or Not Present to indicate the status of fan A. The graph of this measure however, represents the status of fan A using the numeric equivalents - 0 or 1.
Fan_B_state This measure indicates the current state of Fan B.   If the fan B is unavailable, then this measure will return the value Not Present. On the other hand, if fan B is available, then the value of this measure will be Present.

The numeric values that correspond to each of the states discussed above are as follows:

Value State
1 Present
0 Not Present

Note:

By default, this measure reports the values Present or Not Present to indicate the status of fan B. The graph of this measure however, represents the status of fan B using the numeric equivalents - 0 or 1.
Power_A_state This measure indicates the current state of the power supply unit A.   If power unit A is unavailable, then this measure will return the value Not Present. On the other hand, if power unit A is available, then the value of this measure will be Present.

The numeric values that correspond to each of the states discussed above are as follows:

Value State
1 Present
0 Not Present

Note:

By default, this measure reports the values Present or Not Present to indicate the status of power supply unit A. The graph of this measure however, represents the status of unit A using the numeric equivalents - 0 or 1.
Power_B_state This measure indicates the current state of the power supply unit B.   If power unit B is unavailable, then this measure will return the value Not Present. On the other hand, if power unit B is available, then the value of this measure will be Present.

The numeric values that correspond to each of the states discussed above are as follows:

Value State
1 Present
0 Not Present

Note:

By default, this measure reports the values Present or Not Present to indicate the status of power supply unit B. The graph of this measure however, represents the status of unit B using the numeric equivalents - 0 or 1.
LCC_A_state This measure indicates the current state of the LCC A.   If LCC A is unavailable, then this measure will return the value Not Present. On the other hand, if LCC A is available, then the value of this measure will be Present.

The numeric values that correspond to each of the states discussed above are as follows:

Value State
1 Present
0 Not Present

Note:

By default, this measure reports the values Present or Not Present to indicate the status of LCC A. The graph of this measure however, represents the status of LCC A using the numeric equivalents - 0 or 1.
LCC_B_state This measure indicates the current state of the LCC B.   If LCC B is unavailable, then this measure will return the value Not Present. On the other hand, if LCC B is available, then the value of this measure will be Present.

The numeric values that correspond to each of the states discussed above are as follows:

Value State
1 Present
0 Not Present

Note:

By default, this measure reports the values Present or Not Present to indicate the status of LCC B. The graph of this measure however, represents the status of LCC B using the numeric equivalents - 0 or 1.