Agents Administration - Tests
 

Configuration of ACCertTest

This test captures the expiry date of all active certificates, computes how long each active certificate will remain valid, and proactively alerts administrators if any certificate is nearing expiry.

The default parameters associated with this test are:

  • The TEST PERIOD list box helps the user to decide how often this test needs to be executed.

  • Specify the host for which the test is to be configured in the HOST text box.

  • In the PORT text box, specify the port at which the specified HOST listens to. By default, this is 1494.

  • By default, the REPORT ONLY ACTIVE CERTIFICATES flag is set to Yes, indicating that this test reports the validity of active certificates only. To ensure that the test reports the validity of all certificates, set this flag to No.

  • To pull out metrics, this test needs to login to the AppController's management console as a user with Administrator rights to AppController. For this purpose, you need to configure this test with the USERNAME and PASSWORD of a user with Administrator rights to the AppController.

  • Confirm the PASSWORD by retyping it in the CONFIRM PASSWORD text box.

  • Indicate whether/not AppController is SSL-enabled. By default, the SSL flag is set to Yes.

  • To make diagnosis more efficient and accurate, the eG Enterprise suite embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the DETAILED DIAGNOSIS capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option.

    The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:

    • The eG manager license should allow the detailed diagnosis capability
    • Both the normal and abnormal frequencies configured for the detailed diagnosis measures should not be 0.
  • If multiple components of the same component type are awaiting configuration, then an APPLY TO OTHER COMPONENTS check box will appear in this page. Clicking on this check box will allow you to apply the configuration to all/selected components of that type.

  • Once the necessary values have been provided, clicking on the UPDATE button will register the changes made.

When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of "none" in the parameter value indicates that the corresponding parameter value can be changed if required.