Configuration
of IbmDsArrayStsTest
The IbmDsArrayStsTest reports the current state of the target storage subsystem, and proactively alerts administrators to failures and space inadequacies experienced by the subsystem.
The parameters of this test are as follows:
-
The test uses the command-line utility, SMcli.exe, to collect the required statistics from the IBM DS Raid Storage device. To enable the test to run the SMcli.exe, provide the full path to the exe in the SMCLILOCATION text box.
Note:If the SMcli.exe resides in say, C:\Program Files\IBM_DS\client, your smclilocation should be: C:\Progra~1\IBM_DS\client. On the other hand, if the SMcli.exe resides in say, C:\Program Files (x86)\IBM_DS\client, your smclilocation should be: C:\Progra~2\IBM_DS\client.
-
By default, the ALTERNATE CONTROLLER IP text box is set to none. This implies that by default, the storage device being monitored supports a single controller only, and the IP address of this controller is the same as the IP address of the target HOST. Sometimes, a storage device could be configured with two/more controllers, so as to provide fail-over services - in other words, if the primary controller is down, then one of the alternate controllers will take over from the primary to provide the critical storage services. In this case, you can provide a comma-separated list of alternate controller IPs in the ALTERNATE CONTROLLER IP text box.
-
To make diagnosis more efficient and accurate, the eG Enterprise suite embeds an optional DETAILED DIAGNOSIS capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the ON option. To disable the capability, click on the OFF option.
The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
- The eG manager license should allow the detailed diagnosis capability.
- Both the normal and abnormal frequencies configured for the detailed diagnosis measures should not be 0.
When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of "none" in the parameter value indicates that the corresponding parameter value can be changed if required.
|