Agents Administration - Tests
 

Configuration of StrmProcessEventTest

The test monitors the target PVS server and promptly captures the average and maximum time taken by the target devices to complete the boot process. In addition, this test also reveals the count of devices that are booted successfully and the number of devices that are slow at boot process. These metrics will ease troubleshooting when validating PVS functionality as well as when tracking down potential issues in the boot process.

The default parameters associated with this test are:

  • The TEST PERIOD list box helps the user to decide how often this test needs to be executed.

  • In the HOST text box, specify the IP address of the host for which the test is being configured.

  • In the PORT text box, specify the port used by the Citrix Provisioning server. By default, this is 54321.

  • Specify the maximum duration (in seconds) for which a boot process should have completed for it to be accepted as successful in MAX ACCEPTABLE BOOT TIME IN SECONDS textbox. The default value is 60.

  • The DD FREQUENCY refers to the frequency with which detailed diagnosis measures are to be generated for this test. The default is 1:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. You can modify this frequency, if you so desire. Also, if you intend to disable the detailed diagnosis capability for this test, you can do so by specifying none against DD FREQUENCY.

  • To make diagnosis more efficient and accurate, eG embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test, by default, for a particular server, choose the On option against DETAILED DIAGNOSIS. To disable the capability, click on the Off option.

    The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:

    • The eG manager license should allow the detailed diagnosis capability.

    • Both the bad and normal frequencies configured for the detailed diagnosis measures should not be 0.

  • If multiple components of the same component type are awaiting configuration, then an APPLY TO OTHER COMPONENTS button will appear in this page. Clicking on this button will allow you to apply the configuration to all/selected components of that type.

  • Once the necessary values have been provided, clicking on the UPDATE button will register the changes made.

When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of “none” in the parameter value indicates that the corresponding parameter value can be changed if required.