Configuration of EMCPvMeCtlEPtStTest
An Expander Port refers to the connection slot(s) used to connect the storage system or unit to multiple storage systems or units. Since the expander ports play a crucial role in expanding the storage capacity of a storage solution, error-prone ports, disconnected ports, or faulty/degraded ports, can deny remote hosts access to the additional storage capacity that has been made available via these ports. To prevent this, administrators will have to rapidly detect port-related abnormalities and swiftly initiate measures to correct them, so that the expanded ports, and through them the attached storage systems, are always accessible. To capture these abnormalities and instantly bring them to the attention of administrators, use the EMCPvMeCtlEPtStTest. For every expanded port in the storage system, this test reports the current status and overall health of the port, and thus leads administrators to defective ports.
The default parameters associated with this test are:
In the HOST text box, specify the HOST for which this test is to be configured. Since the storage device is managed using the IP address of its storage controller, the same will be displayed as host. In case of a dual-controller configuration, the IP address of the primary controller will be displayed here.
By default, this test always connects to the Host to collect metrics. If the Host is unavailable, then the test will not be able to execute. This is because, the Additional Controller IP is set to none by default.
If the monitored storage device has two controllers, then you can configure the test to connect to an alternate controller, if the host is unreachable. For this purpose, specify the IP address of the alternate controller in the Additional Controller IP text box.
In order to monitor a EMC PowerVault ME storage system, the eG agent has to be configured with the credentials of a user who has been assigned the Monitor role. Specify the login credentials of such a user in the USER and PASSWORD text boxes. To know how to create such a user, refer to Pre-requisites-for-monitoring-the-EMC PowerVault-ME-storage-system. Confirm the password by retyping it in CONFIRM PASSWORD text box.
The Management Controller of the EMC PowerVault ME storage system provides access for monitoring and management via the HTTP and HTTPS protocols for XML API request/response semantics. To enable the eG agent to access the management controller, invoke the XML API commands, and collect the required metrics, you need to specify the SERVICE PORT on the controller that listens for HTTP/HTTPS requests for XML API semantics. By default, this is port 80.
By default, EMC PowerVault ME system is not SSL-enabled. This is why, SSL flag is set to False by default. If it is SSL-enabled, then change this flag to True.
To make diagnosis more efficient and accurate, eG embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test, by default, for a particular server, choose the On option against DETAILED DIAGNOSIS. To disable the capability, click on the Off option.
The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of “none” in the parameter value indicates that the corresponding parameter value can be changed if required.
|