This test captures and reports the count and complete details of slow commands, along with the duration per command, thus enabling administrators to quickly identify the command that is the slowest. Additionally, the test helps administrators review the maximum length configuration of the slow log, and the threshold set for capturing slow commands, so that the administrators can determine if these settings need to be tweaked.
The default parameters associated with this test are:
In some high security environments, a password may have been set for the Redis server, so as to protect it from unauthorized accesses/abuse. If such a password has been set for the monitored Redis server, then specify that password against REDIS PASSWORD. Then, confirm the password by retyping it against CONFIRM PASSWORD.
If the Redis server is not password protected, then do not disturb the default setting of this parameter.
To determine whether/not the target Redis server is password-protected, do the following:
Login to the system hosting the Redis server.
Open the redis.conf file in the <REDIS_INSTALL_DIR>.
Look for the requirepass parameter in the file.
If this parameter exists, and is not preceded by a # (hash) symbol, it means that password protection is enabled for the Redis server. In this case, the string that follows the requirepass parameter is the password of the Redis server. For instance, say that the requirepass specification reads as follows:
requirepass red1spr0
According to this specification, the Redis server is protected using the password red1spr0. In this case therefore, you need to specify red1spr0 against REDIS PASSWORD.
-
On the other hand, if the requirepass parameter is prefixed by the # (hash) symbol as shown below, it means password protection is disabled.
# requirepass red1spr0
In this case, leave the REDIS PASSWORD parameter with its default setting.
The DETAILED DIAGNOSIS makes diagnosis more efficient and accurate, the eG Enterprise suite embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option.
The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
- The eG manager license should allow the detailed diagnosis capability
- Both the normal and abnormal frequencies configured for the detailed diagnosis measures should not be 0
When changing default configurations of tests, the values with “$” indicate variables that will be replaced by the eG system according to the specific server being managed - for instance, $hostName is the host/nickname of the target host, $port is the port number of the server being monitored. E.g., for a server xyz:80, $hostName will be changed automatically by the eG manager to “xyz*” and $port will be changed to “80” when configuring a test.
|