Measures reported by StratusHwTrapTest

This test monitors the staus of various hardware elements present in the Stratus server using SNMP traps.

Measurement Description Measurement Unit Interpretation
Empty Indicates that a slot in the system is in an "empty" state Boolean For a slot, this state indicates that the slot is empty, physically not present, or electrically inaccessible. If the empty device causes the system to be go into simplex mode, the device is no longer fault tolerant. In some cases this state represents both a slot and a device. For instance, an instance of an SRA_DIMM in the Empty state means that a slot exists for the DIMM, but that the slot is empty. DIMMs, CPU Boards, IO Boards and Processors are represented by such WMI objects. Sensors go to this state instead of the"Not Present" state when they are not present. Empty devices are generally enumerable.
Not_present Indicates that a device in the system is in a "not present" state Boolean This state indicates that a device is either physically not present or electrically inaccessible. For instance, pulling the power cord on a CPU board makes the DIMMs and Processors on the board go to this state. When a WMI object goes to this state, it is generally not enumerable. Thus, this state only appears in state change events.
Removed Indicates that a device in the system is in a "removed" state. Usually, this is a final state but it can be a transient state. Boolean Usually, this state indicates that a device was intentionally removed from service. When intentionally removed from service, the device remains in this state. Only some devices go to this state when removed from services; other devices go to other offline states. Some devices pass through this state as they are brought online.
Dumping Indicates that a device is in a "Dumping" state. This is a transient state. Boolean This state indicates a device is in the process of writing a dump to a file.
Diagnostics_passed Indicates that a device is in a "Diagnostic Passed" state. This is a transient state and the device should change to "online" state when it is brought online. Boolean This state indicates that a device has just completed its diagnostics tests.
Initialising Indicates that a device is in a "Initialising" state. This is a transient state and the device should change to "online" state when it is brought online. Boolean This state indicates that a device is in the process of initializing.
Syncing Indicates that a device is in a "synching" state. This is a transient state and the device should change to "online" state when it is brought online. Boolean This state indicates that a device is synchronizing itself with its partners. For instance, when a CPU is brought up, it synchronizes its memory and its processor state with that of its partners.
Offline Indicates that a device is in a "offline" state Boolean This state indicates that a device is offline. Only some devices can go to this state while other devices go into the "Removed From Service" state.
Firmware_update_complete Indicates that a device's firmware update procedure has completed Boolean  
Diagnostics Indicates that a device is running diagnostics Boolean  
Online Indicates that a device is in a "online" state Boolean This state indicates that the device is online, but not configured for redundancy. For instance, a working NIC that is not part of a team will be in this state. Although the online state does not indicate whether a device is safe-to-pull or not, on a properly configured system such devices can be assumed safe-to-pull.
Simplex Indicates that a device is in a "Simplex" state Boolean This state indicates that a device is online, configured for redundancy, and is not safe-to-pull. When applied to a port, indicates that the port is configured for redundancy, and that whatever is connected to the port is not safe-to-pull.
Duplex Indicates that a device is in a "Duplex" state Boolean This state indicates that a device is online, configured for redundancy, and is safe-to-pull. When applied to a port, indicates that the port is configured for redundancy, and that whatever is connected to the port is safe-to-pull.
Shot Indicates that a device is in a "Shot" state. This is a transient state and the device should either transit to "broken" or "online" state after diagnostic is done. Boolean This state indicates a device experienced a problem and will soon move to either an online state or the broken state.
Broken Indicates that a device is in a "Broken" state Boolean This state Indicates that a device is broken. In the case of a port, this state may mean that the port is inoperative or that that which attaches to the port is inoperative. There are several reasons that a device could be broken but usually points to hardware errors. Contact your service providers for service checks. In the case where the device is a port, it usually indicates that there is nothing attached to the port, or when whatever should be attached to the port is not responding. For example, a NIC port will be in this state when it cannot detect link.