eG Monitoring
 

Measures reported by VCFlxDomainTest

A VC Flex domain group is a collection of domains with common Ethernet and Fibre Channel interconnects, and with uplinks to the same LANs and SANs. Establishing a VC Flex domain group allows you to upgrade, replace, or move multiple servers within their enclosures without changes to the external LAN/SAN environments. With HP's Virtual Connect Enterprise Manager (VCEM), you can move and copy profiles within a single VC Flex domain, among any VC Flex domains, or among VC Flex domain groups.

VC Flex domain grouping allows you to use a master configuration to deploy and maintain multiple VC Flex domains that access the same networks. This increases infrastructure consistency and simplifies deploying new enclosures and domains, whether they are single-enclosures or multi-enclosures VC Flex domains. The VCFlxDomainTest monitors the domains and reports the status of the Virtual Connect Flex Domain and its redundancy state.

Outputs of the test: One set of results for each Domain of the target HP VC Flex.

Descriptor: Domain

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
Domain_status Indicates the current status of this domain.  

The values reported by this measure and its numeric equivalents are mentioned in the table below:

Measure Value Numeric Value
Info 0
Unknown 1
Normal 2
Warning 3
Minor 4
Major 5
Disabled 6
Critical 7

Note:

By default, this measure reports the Measure Values listed in the table above to indicate the current status of the Virtual Connect Flex Domain.

Domain_redundant_st Indicates the overall redundancy status of this domain.  

The values reported by this measure and its numeric equivalents are mentioned in the table below:

Measure Value Numeric Value
No 0
Yes 1

Note:

By default, this measure reports the Measure Values listed in the table above to indicate the current status of the Virtual Connect Flex Domain.