eG Monitoring
 

Measures reported by XIOSCSASPortTest

This test auto-discovers the SAS ports of the Storage Controller and reports the current state of the Storage Controller. This test also reports the current health of each SAS port.

Outputs of the test : One set of results for each Storage Controller:SAS Port of the target EMC XtremIO being monitored.

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
sasHBAPortHealth Indicates the health of this SAS port available in the Storage Controller.   The values reported by this measure and its numeric equivalents are mentioned in the table below:

Measure Value Numeric Value
Level_1_clear 0
Level_2_unknown 1
Level_3_warning 2
Level_4_minor 3
Level_5_major 4
Level_6_critical 5

Note:

By default, this measure reports the Measure Values listed in the table above to indicate the health of this SAS port available in the Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 or 5.

sasPortSt Indicates the current state of this SAS port available in the Storage Controller.   The values reported by this measure and its numeric equivalents are mentioned in the table below:

Measure Value Numeric Value
Up 0
Down 1

Note:

By default, this measure reports the Measure Values listed in the table above to indicate the current state of this SAS port available in the Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 to 1.