Measures reported by HwPowerSupplyTest
With the help of this measure, you can promptly detect the potential failure of any of the power supply units of a server. This test executes only on IBM/Dell servers.
The measures
made by this test are as
follows:
| Measurement |
Description |
Measurement Unit |
Interpretation |
| Status |
Indicates the current status of this power supply unit. |
|
The values this measure can report and their numeric equivalents are available in the table below:
| Measure Value |
Numeric Value |
| Normal |
0 |
| Other |
1 |
| Unknown |
2 |
| Non Critical |
4 |
| Non Critical |
4 |
| Critical |
5 |
| Non Recoverable |
6 |
Note:
This measure reports the Measure Values listed in the table above to indicate the current status of a power supply unit. However, in the graph of this measure, status is indicated using only the Numeric Values listed in the above table. |
| Sensor_state |
Indicates the current state of this power supply sensor. |
|
The values this measure can report and their numeric equivalents are available in the table below:
| Measure Value |
Numeric Value |
| Present |
1 |
| PsFailure Detected |
2 |
| Predictive Failure |
4 |
| PsACLost |
8 |
| acLostOrOutOfRange |
16 |
| acOutOfRangeButPresent |
32 |
| Configuration Error |
64 |
Note:
This measure reports the Measure Values listed in the table above to indicate the current state of a sensor. However, in the graph of this measure, sensor state is indicated using only the Numeric Values listed in the above table. |
| Output |
Indicates the maximum sustained output wattage of the power supply, in tenths of watts. |
Watts |
|
|