| Measurement |
Description |
Measurement
Unit |
Interpretation |
| OperState |
Indicates the overall status of this PSU present in this chassis.
|
|
This measure reports the status of the PSUs and their numeric equivalents as shown in the table:
| Numeric Value |
State |
| 0 |
Unknown |
| 1 |
Operable |
| 2 |
Inoperable |
| 3 |
Degraded |
| 4 |
Powered-off |
| 5 |
Power-problem |
| 6 |
Removed |
| 7 |
Voltage-problem |
| 8 |
Thermal-problem |
| 9 |
Performance-problem |
| 10 |
Accessibility-problem |
| 11 |
Identity-unestablishable |
| 12 |
Bios-post-timeout |
| 13 |
Disabled |
| 51 |
Fabric-conn-problem |
| 52 |
Fabric-unsupported-conn |
| 81 |
Config |
| 82 |
Equipment-problem |
| 83 |
Decommissioning |
| 84 |
Chassis-limit-exceeded |
| 101 |
Discovery |
| 102 |
Discovery-failed |
| 103 |
Identify |
| 104 |
Post-failure |
| 105 |
Upgrade-problem |
| 106 |
Peer-comm-problem |
| 107 |
Auto-upgrade |
Note:By default, this measure reports the above-mentioned States while indicating the status of the PSUs in this chassis. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states as mentioned in the table above.
The detailed diagnosis of this measure provides the Time, ID, PID, Revision, Serial Number and Vendor attributes for the PSUs in this chassis. |
| Operability |
Indicates the operating state of this PSU present in this chassis.
|
|
This measure reports the operating state of the PSUs and their numeric equivalents as shown in the table:
| Numeric Value |
State |
| 0 |
Unknown |
| 1 |
Operable |
| 2 |
Inoperable |
| 3 |
Degraded |
| 4 |
Powered-off |
| 5 |
Power-problem |
| 6 |
Removed |
| 7 |
Voltage-problem |
| 8 |
Thermal-problem |
| 9 |
Performance-problem |
| 10 |
Accessibility-problem |
| 11 |
Identity-unestablishable |
| 12 |
Bios-post-timeout |
| 13 |
Disabled |
| 51 |
Fabric-conn-problem |
| 52 |
Fabric-unsupported-conn |
| 81 |
Config |
| 82 |
Equipment-problem |
| 83 |
Decommissioning |
| 84 |
Chassis-limit-exceeded |
| 101 |
Discovery |
| 102 |
Discovery-failed |
| 103 |
Identify |
| 104 |
Post-failure |
| 105 |
Upgrade-problem |
| 106 |
Peer-comm-problem |
| 107 |
Auto-upgrade |
Note:By default, this measure reports the above-mentioned States while indicating the operating state of the PSUs in this chassis. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states as mentioned in the table above. |
| Performance |
Indicates the current performance status of this PSU present in this chassis.
|
|
This measure reports the current performance status of the PSUs and their numeric equivalents as shown in the table:
| Numeric Value |
State |
| 0 |
Unknown |
| 1 |
Ok |
| 2 |
Upper-non-recoverable |
| 3 |
Upper-critical |
| 4 |
Upper-non-critical |
| 5 |
Lower-non-critical |
| 6 |
Lower-critical |
| 7 |
Lower non-recoverable |
Note:By default, this measure reports the above-mentioned States while indicating the performance status of the PSUs in this chassis. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states as mentioned in the table above. |
| Power |
Indicates the power status of this PSU present in this chassis.
|
|
This measure reports the power status of the PSUs and their numeric equivalents as shown in the table:
| Numeric Value |
State |
| 0 |
Unknown |
| 1 |
On |
| 2 |
Test |
| 3 |
Off |
| 4 |
Online |
| 5 |
Offline |
| 6 |
Offduty |
| 7 |
Degraded |
| 8 |
Power-save |
| 9 |
Error |
Note:By default, this measure reports the above-mentioned States while indicating the power status of the PSUs in this chassis. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states i.e., 0 to 10. |
| Presence |
Indicates the current state of this PSU present in this chassis.
|
|
This measure reports the current state of the PSUs and their numeric equivalents as shown in the table:
| Numeric Value |
State |
| 0 |
Unknown |
| 1 |
Empty |
| 10 |
Equipped |
| 11 |
Missing |
| 12 |
Mismatch |
| 13 |
Equipped-not-primary |
| 20 |
Equipped-identity-unestablishable |
| 30 |
Inaccessible |
| 40 |
Unauthorized |
Note:By default, this measure reports the above-mentioned States while indicating the current state of the PSUs in this chassis. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states as mentioned in the table above. |
| ThermalState |
Indicates the thermal state of this PSU present in this chassis.
|
|
This measure reports the thermal state of the PSUs and their numeric equivalents as shown in the table:
| Numeric Value |
State |
| 0 |
Unknown |
| 1 |
Ok |
| 2 |
Upper-non-recoverable |
| 3 |
Upper-critical |
| 4 |
Upper-non-critical |
| 5 |
Lower-non-critical |
| 6 |
Lower-critical |
| 7 |
Lower non-recoverable |
Note:By default, this measure reports the above-mentioned States while indicating the thermal state of the PSUs in this chassis. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states as mentioned in the table above. |
| Voltage |
Indicates the voltage state of this PSU present in this chassis.
|
|
This measure reports the voltage state of the PSUs and their numeric equivalents as shown in the table:
| Numeric Value |
State |
| 0 |
Unknown |
| 1 |
Ok |
| 2 |
Upper-non-recoverable |
| 3 |
Upper-critical |
| 4 |
Upper-non-critical |
| 5 |
Lower-non-critical |
| 6 |
Lower-critical |
| 7 |
Lower non-recoverable |
Note:By default, this measure reports the above-mentioned States while indicating the voltage state of the PSUs in this chassis. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states as mentioned in the table above. |
| Ambient_temp |
Indicates the internal temperature of the PSUs present in this chassis.
|
Celcius |
A high temperature is not preferred as it may cause severe damage to the PSUs and therefore cause performance bottleneck in the Cisco UCS chassis. |
| Input210v |
Indicates the input voltage of the PSUs present in the chassis.
|
Volts |
Any value higher than 210 volts could indicate a problem condition that may require further investigation. |
| Output12v |
Indicates the output voltage of the PSUs present in the chassis.
|
Volts |
Any value higher than 12 volts could indicate a problem condition that may require further investigation. |
| Output3v3 |
Indicates the output voltage of the PSUs present in the chassis.
|
Volts |
Any value higher than 3.3 volts could indicate a problem condition that may require further investigation. |
| Output_current |
Indicates the output current of the PSUs present in the chassis.
|
Amps |
Ideally, the value of this measure should be low. A sudden/consistent increase in this value could warrant an investigation. |
| Output_power |
Indicates the output power of the PSUs present in each chassis.
|
Watts |
Ideally, the value of this measure should be low. A sudden/consistent increase in this value could warrant an investigation. |