eG Monitoring
 

Measures reported by CpqRackPsTest

This test monitors every power supply unit in each rack blade of a blade server, and reports the availability, operational status, and current power of each unit.

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
Rack_ps_status Indicates the current status of this power supply unit Number The table below lists the values that this measure can report, and the states they indicate:
Value State
1 noError
2 generalFailure
3 bistFailure
4 fanFailure
5 tempFailure
6 interlockOpen
7 epromFailed
8 vrefFailed
9 dacFailed
10 ramTestFailed
11 voltageChannelFailed
12 orringdiodeFailed
13 brownOut
14 giveupOnStartup
15 nvramInvalid
16 calibrationTableInvalid
Input_line_status Indicates the current status of the input line of this power supply unit Number The table below lists the values that this measure can report, and the states they indicate:
Value State
1 noError
2 lineOverVoltage
3 LineUnderVoltage
4 lineHit
5 brownOut
6 linePowerLoss
Max_power Indicates the maximum power output of this power supply unit Watts  
Curr_power Indicates the current power output of this power supply unit Watts By comparing the value of this measure across power supply units, you can quickly identify the unit that is producing the maximum power output currently, and the rack blade with which it is associated.
Power_supply_present_st Indicates the availability of this power supply unit Number The table below lists the values that this measure can report, and the states they indicate:
Value State
1 Other
2 Absent
3 Present
Power_supply_condition Indicates the current condition of this power supply unit Number The table below lists the values that this measure can report, and the states they indicate:
Value State Description
1 Other The status could not be determined or not present
2 OK The power supply is operating normally
3 Degraded A temperature sensor, fan or other power supply component is outside of normal operating range
4 Failed A power supply component detects a condition that could possibly damage the system