Measures reported by CpqEnclDetailsTest

A blade enclosure, which can hold multiple blade servers, provides services such as power, cooling, networking, various interconnects and management—though different blade providers have differing principles around what to include in the blade itself (and sometimes in the enclosure altogether).

This test monitors each blade enclosure, and reports its current state and its contents.

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
Encl_cond Indicates the current conditions of the enclosure Number The table below lists the values that this measure can report, and the states they indicate:
Value State Description
1 Other No temperature sensors, fans, or fuses in the enclosure or the state could not be determined.
2 OK All temperature sensors, fans, and fuses are within the normal operating range
3 Degraded One or more temperature sensors, fans, or fuses are outside of the normal operating range, but none failed.
4 Failed The temperature sensor exceeded the critical threshold value, a required fan has failed, or a fuse has been tripped. The system will automatically shutdown if the failed condition results.
Encl_has_blade Indicates whether the enclosure has server blades or not Number If the enclosure consists of one/more server blades, then this measure will report the value 1. The value 0 on the other hand indicates that the enclosure does not have any blades.
Encl_has_pwr Indicates whether the enclosure contains power supply units or not Number If the enclosure consists of one/more power supply units, then this measure will report the value 1. The value 0 on the other hand indicates that the enclosure does not have any power supply units.
Encl_has_temp_sensor Indicates whether the enclosure contains temperature sensors or not Number If the enclosure consists of one/more temperature sensors, then this measure will report the value 1. The value 0 on the other hand indicates that the enclosure does not have any temperature sensors.
Encl_has_net_connector Indicates whether the enclosure contains net connectors or not Number If the enclosure consists of one/more net connectors, then this measure will report the value 1. The value 0 on the other hand indicates that the enclosure does not have any net connectors.
Encl_has_fan Indicates whether the enclosure contains fans or not Number If the enclosure consists of one/more fans, then this measure will report the value 1. The value 0 on the other hand indicates that the enclosure does not have any fans.
Encl_has_fan Indicates whether the enclosure contains fans or not Number If the enclosure consists of one/more fans, then this measure will report the value 1. The value 0 on the other hand indicates that the enclosure does not have any fans.
Encl_has_fuse Indicates whether the enclosure contains fuses or not Number If the enclosure consists of one/more fuses, then this measure will report the value 1. The value 0 on the other hand indicates that the enclosure does not have any fuses.