Agents Administration - Tests
 

Configuration of AWSAmazon24HrS3Test

This test automatically discovers the buckets that have been created in every region and reports the total count and size of objects in each bucket. You can then use the detailed diagnosis of this test to know in which storage classes each bucket is currently storing objects, and the total size of objects in each class.

The default parameters associated with this test are:

  • The TEST PERIOD list box helps the user to decide how often this test needs to be executed.

  • Specify the host for which the test is to be configured in the HOST text box.

  • To monitor an Amazon EC2 instance, the eG agent has to be configured with the access key and secret key of a user with a valid AWS account. For this purpose, we recommend that you create a special user on the AWS cloud, obtain the access and secret keys of this user, and configure this test with these keys. To know the procedure for this, click here. Specify the access key and secret key so obtained in the AWS ACCESS KEY and AWS SECRET KEY text boxes. Make sure you reconfirm the access and secret keys you provide here by retyping it in the CONFIRM AWS ACCESS KEY and CONFIRM AWS SECRET KEY text boxes.

  • In some environments, all communication with the AWS EC2 cloud and its regions could be routed through a proxy server. In such environments, you should make sure that the eG agent connects to the cloud via the proxy server and collects metrics. To enable metrics collection via a proxy, specify the IP address of the proxy server and the port at which the server listens against the PROXY HOST and PROXY PORT parameters. By default, these parameters are set to none, indicating that the eG agent is not configured to communicate via a proxy, by default.

  • If the proxy server requires authentication, then, specify a valid proxy user name and password in the PROXY USER NAME and PROXY PASSWORD parameters, respectively. Then, confirm the password by retyping it in the CONFIRM PASSWORD text box. By default, these parameters are set to none, indicating that the proxy sever does not require authentication by default.

  • If a Windows NTLM proxy is to be configured for use, then additionally, you will have to configure the Windows domain name and the Windows workstation name required for the same against the PROXY DOMAIN and PROXY WORKSTATION parameters. If the environment does not support a Windows NTLM proxy, set these parameters to none.

  • In the EXCLUDE REGION text box, you can provide a comma-separated list of region names or patterns of region names that you do not want to monitor. For instance, to exclude regions with names that contain ‘east’ and ‘west’ from monitoring, your specification should be: *east*,*west*.

  • To make diagnosis more efficient and accurate, eG embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test, by default, for a particular server, choose the On option against DETAILED DIAGNOSIS. To disable the capability, click on the Off option.

    The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:

    • The eG manager license should allow the detailed diagnosis capability.

    • Both the bad and normal frequencies configured for the detailed diagnosis measures should not be 0.

  • If multiple components of the same component type are awaiting configuration, then an APPLY TO OTHER COMPONENTS check box will appear in this page. Clicking on this check box will allow you to apply the configuration to all/selected components of that type.

  • Once the necessary values have been provided, clicking on the UPDATE button will register the changes made.

When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of "none" in the parameter value indicates that the corresponding parameter value can be changed if required.