Agents Administration - Tests
 

Configuration of SecGrpMgntTest

This test keeps track of changes made to groups and members, and promptly notifies administrators when such changes are made. Moreover, the detailed diagnosis of the test also reveals the details of the changes – for instance, if a global group is created, then detailed metrics provided by the test indicate which group was created and which user created the group. This enables administrators to determine whether/not the change was made by an authorized user.

The default parameters associated with this test are as follows:

  • The TEST PERIOD list box helps the user to decide how often this test needs to be executed.

  • Specify the IP address of the machine where the Active Directory is installed, in the HOST text box.

  • The port number through which the Active Directory communicates, in the PORT text box. The default port number is 389.

  • The DD FREQUENCY refers to the frequency with which detailed diagnosis measures are to be generated for this test. The default is 1:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. You can modify this frequency, if you so desire. Also, if you intend to disable the detailed diagnosis capability for this test, you can do so by specifying none against DD FREQUENCY.

  • To make diagnosis more efficient and accurate, the eG Enterprise suite embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the DETAILED DIAGNOSIS capability of this test for a particular server, choose the On option. To disable the capability, click on the Off option.

    The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:

    • The eG manager license should allow the detailed diagnosis capability.

    • Both the normal and abnormalfrequencies configured for the detailed diagnosis measures should not be 0.

  • If multiple components of the same component type are awaiting configuration, then an APPLY TO OTHER COMPONENTS check box will appear in this page. Clicking on this check box will allow you to apply the configuration to all/selected components of that type.

  • Once the necessary values have been provided, clicking on the UPDATE button will register the changes made.

When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$“ or contain a series of “*”. A value of "none" in the parameter value indicates that the corresponding parameter value can be changed if required.