Configuration of ClariionHBATest
Using this test, you can verify whether the HBA ports are currently connected to the fibre channel or not, and identify ports that are not trusted or defined.
The default parameters associated with this test are as follows:
- The TEST PERIOD list box helps the user to decide how often this test needs to be executed.
- In the HOST text box, the host name of the server for which the test is to be configured has to be specified.
-
By default, the HOST IP will be displayed in the CLARIION IP text box. If at a later point in time, the IP address of the device changes, you can change the CLARIION IP accordingly.
-
The eG agent uses the command-line utility, NaviSecCli.exe, which is part of the NaviSphere Management Suite, to communicate with and monitor the storage device. To enable the eG agent to invoke the CLI, configure the full path to the CLI in the NAVISECCLIPATH text box.
This test reports measures for each HBA port on the storage system. By default, the test represents a HBA port as a unique combination of the Server name (i.e., the name of the server with which the HBA port is connecting), the Storage Processor name, and the Storage Processor ID. For instance, if the server named nlpc20234 is connecting to the storage system via an HBA port using the storage processor, SP A, with ID 0, then, by default, this HBA port will be represented as nlpc20234 / SP A 0, in the eG monitoring console. If you want to append the HBA device name also to this representation, then, set the SHOW DEVICE NAME flag to Yes. By default, this flag is set to No.
-
DD FREQUENCY refers to the frequency with which detailed diagnosis measures are to be generated for this test. The default is 4:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. You can modify this frequency, if you so desire. Also, if you intend to disable the detailed diagnosis capability for this test, you can do so by specifying none against DD FREQUENCY.
To make diagnosis more efficient and accurate, the eG system embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option against DETAILED DIAGNOSIS. To disable the capability, click on the Off option.
The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of "none" in the parameter value indicates that the corresponding parameter value can be changed if required.
|