Configuration
of XDVDLoginTest
This test monitors the logins to virtual desktops managed by all controllers in a XenDesktop broker farm and reports the total number of logins and logouts.
The default parameters associated with this test are as follows:
- The TEST PERIOD list box helps the user to decide how often this test needs to be executed.
- In the HOST text box, the host name of the server for which the test is to be configured has to be specified.
By default, the ISFARMSERVER flag is set to Yes, indicating that the monitored server is the farm server of a controller farm. For a farm server, this test will report metrics at the farm-level - accordingly, a set of metrics will be reported for each controller in the farm. On the other hand, if the monitored controller is only a member of a farm and not the farm server, then set this flag to No. In this case, the test will report metrics for the monitored controller only and not for every controller in the farm.
The DDFREQ refers to the frequency with which detailed diagnosis measures are to be generated. The default is 1:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. The DDFREQ refers to the frequency with which detailed diagnosis measures are to be generated. The default is 1:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. Typically, detailed diagnosis frequencies are set globally, using the DIAGNOSIS CONFIGURATION page that appears when the Configure -> Diagnosis menu sequence is followed. This global setting can be overridden at the test-level using the DDFREQ parameter. To disable the detailed diagnosis capability for a test, you can set this parameter to none.
To make diagnosis more efficient and accurate, the eG system embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option against DETAILED DIAGNOSIS. To disable the capability, click on the Off option.
The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of "none" in the parameter value indicates that the corresponding parameter value can be changed if required.
|