Agents Administration - Tests
 

Configuration of SystemTest

The default parameters associated with this test are as follows:

  • The TEST PERIOD list box helps the user to decide how often this test needs to be executed.

  • In the HOST text box, the host name of the server for which the test is to be configured has to be specified.

  • The DURATION text box determines the period (in seconds) for which the test runs each time.

  • The SUMMARY attribute is applicable to multi-processor systems only. If the Yes option is selected, then the eG agent will not only report the CPU and memory utilization of each of the processors, but also the summary (i.e., average) of the CPU and memory utilizations of the different processors. If the No option is selected, then the eG agent will report only the CPU usage of the individual processors.  

  • The USEIOSTAT parameter is of significance to Solaris platforms only. By default, the USEIOSTAT flag is set to No. This indicates that, by default, SystemTest reports the CPU utilization of every processor on the system being monitored, and also provides the average CPU utilization across the processors. However, if you want SystemTest to report only the average CPU utilization across processors and across user sessions, then set the USEIOSTAT flag to Yes. In such a case, the processor-wise breakup of CPU utilization will not be available.

  • To make diagnosis more efficient and accurate, the eG system embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the On option against DETAILED DIAGNOSIS. To disable the capability, click on the Off option.

    The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:

    • The eG manager license should allow the detailed diagnosis capability

    • Both the bad and normal frequencies configured for the detailed diagnosis measures should not be 0.

  • If multiple components of the same component type are awaiting configuration, then an APPLY TO OTHER COMPONENTS check box will appear in this page. Clicking on this check box will allow you to apply the configuration to all/selected components of that type.

  • Once the necessary values have been provided, clicking on the UPDATE button will register the changes made.

When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of "none" in the parameter value indicates that the corresponding parameter value can be changed if required.