Configuration of IGELSystemTest
This test collects various metrics pertaining to the CPU and memory usage of every processor supported by each IGEL Endpoint.
The default parameters associated with this test are:
To obtain the ‘inside view’ of performance of the IGEL Endpoints - i.e., to measure the internal performance of the IGEL Endpoints - this test uses a light-weight Endpoint Agent software deployed on each of the IGEL Endpoints. The Endpoint Agents collect performance metrics from the IGEL Endpoints and communicate the metrics to the eG remote agent using TCP protocol. Accordingly, by default, INSIDE VIEW USING parameter is set to TCP.
Against EXCLUDE parameter, you can provide a comma-separated list of disk partitions that you want to exclude from the scope of monitoring. For example, you can use this parameter to exclude temporary disk partitions that the target IGEL Endpoint creates from monitoring. By default, this parameter is set to none indicating that all the system processes will be considered for monitoring by eG Enterprise.
Specify the percentage of time beyond which the test should reveal the detailed diagnosis for the Cpu_util measure. By default, CPU UTILIZATION IN PERCENT parameter is set to 25. However, you can override this value as per your requirement.
The DD FREQUENCY refers to the frequency with which detailed diagnosis measures are to be generated for this test. The default is 1:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. You can modify this frequency, if you so desire. Also, if you intend to disable the detailed diagnosis capability for this test, you can do so by specifying none against DD FREQUENCY.
To make diagnosis more efficient and accurate, eG embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test, by default, for a particular server, choose the On option against DETAILED DIAGNOSIS. To disable the capability, click on the Off option.
The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of “none” in the parameter value indicates that the corresponding parameter value can be changed if required.
|