| Measurement |
Description |
Measurement Unit |
Interpretation |
| cellStatus |
Indicates the current status of the storage cell or target storage server. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| Offline |
0 |
| Online |
100 |
Note:
By default, this measure reports the above-mentioned Measure Values while indicating the current status of the storage cell. However, in the graph of this measure, the status of the storage cell will be represented using the corresponding numeric equivalents only - i.e., 0 or 100. |
| fanStatus |
Indicates the current status of the fan operating in the storage cell. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| Normal |
100 |
| Warning |
90 |
| Critical |
50 |
Note: By default, this measure reports the above-mentioned Measure Values while indicating the current status of the fan. However, in the graph of this measure, the status of the fan will be represented using the corresponding numeric equivalents mentioned in the table above. |
| temperatureStatus |
Indicates the current temperature status of the storage cell. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| Normal |
100 |
| Warning |
90 |
| Critical |
50 |
Note: By default, this measure reports the above-mentioned Measure Values while indicating the current temperature status of the storage cell. However, in the graph of this measure, the temperature status will be represented using the corresponding numeric equivalents mentioned in the table above. |
| powerStatus |
Indicates the current power status of the storage cell. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| Normal |
100 |
| Warning |
90 |
| Critical |
50 |
Note: By default, this measure reports the above-mentioned Measure Values while indicating the current power status of the storage cell. However, in the graph of this measure, the power status will be represented using the corresponding numeric equivalents mentioned in the table above. |
| statusOfCS |
Indicates the current status of the cell server in the storage cell. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| Stopped |
0 |
| Running |
100 |
Note: By default, this measure reports the above-mentioned Measure Values while indicating the current status of the cell server. However, in the graph of this measure, the status of the cell server will be represented using the corresponding numeric equivalents mentioned in the table above. |
| statusOfMS |
Indicates the current status of the management server in the storage cell. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| Stopped |
0 |
| Running |
100 |
Note: By default, this measure reports the above-mentioned Measure Values while indicating the current status of the management server. However, in the graph of this measure, the status of the management server will be represented using the corresponding numeric equivalents mentioned in the table above. |
| statusOfRS |
Indicates the current status of the Restart server in the storage cell. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| Stopped |
0 |
| Running |
100 |
Note: By default, this measure reports the above-mentioned Measure Values while indicating the current status of the Restart server. However, in the graph of this measure, the status of the Restart server will be represented using the corresponding numeric equivalents mentioned in the table above. |
| locatorLEDStatus |
Indicates the current status of the Locator LED. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| Off |
0 |
| On |
100 |
Note: By default, this measure reports the above-mentioned Measure Values while indicating the current status of the Locator LED. However, in the graph of this measure, the status of the Locator LED will be represented using the corresponding numeric equivalents mentioned in the table above. |
| uptime |
Indicates the total time that the storage cell has been up since its last reboot. |
Mins |
Administrators may wish to be alerted if a storage cell has been running without a reboot for a very long period. Setting a threshold for this metric allows administrators to determine such conditions.
|
| uptimeSinceLastMeasure |
The time period that the storage cell has been up since the last time this test ran. |
Secs |
If the storage cell has not been rebooted during the last measurement period and the agent has been running continuously, this value will be equal to the measurement period. If the storage cell was rebooted during the last measurement period, this value will be less than the measurement period of the test. For example, if the measurement period is 300 secs, and if the storage cell was rebooted 120 secs back, this metric will report a value of 120 seconds. The accuracy of this metric is dependent on the measurement period - the smaller the measurement period, greater the accuracy.
|
| isRestarted |
Indicates whether/not the storage cell was restarted. |
|
The table below indicates the values that this measure can report and their corresponding numeric equivalents:
| Measure value |
Numeric Value |
| No |
0 |
| Yes |
1 |
Note: By default, this measure reports the above-mentioned Measure Values while indicating whether/not the storage cell was restarted. However, the graph of this measure will be represented using the corresponding numeric equivalents only. |
| batteryChargeOnDC |
Indicates the percentage of battery charge on the disk controller. |
Percent |
A sudden/gradual decrease in the value of this measure indicates that the battery resource of the disk controller is depleting at a faster pace and the battery needs to be recharged/replaced.
|
| temperatureOnDC |
Indicates the current temperature of the disk controller. |
Celsius |
The temperature of the disk controller should always be maintained in admissible range. A sudden/gradual increase in the temperature results in over heating of the disk controller and eventually causes the storage server to malfunction.
|
| cellTemperature |
Indicates the current temperature of the storage cell. |
Celsius |
Ideally, the value of this measure should be within admissible range. A sudden/gradual increase in the value of this measure results in over heating of the storage cell and eventually causes the storage cell to malfunction.
|
| physicalMemUtil |
Indicates the overall percentage of physical memory utilized by the storage cell. |
Percent |
A value close to 100 is a cause of concern and warrants further investigation.
|
| physicalMemUtilByCS |
Indicates the percentage of physical memory utilized by the cell server. |
Percent |
A high value for this measure indicates that the cell server is consuming too much of physical memory.
|
| physicalMemUtilByMS |
Indicates the percentage of physical memory utilized by the management server. |
Percent |
A high value for this measure indicates that the management server is consuming too much of physical memory.
|
| swapMemoryUsage |
Indicates the percentage of swap memory utilized by the storage cell. |
Percent |
|
| vMemoryUtilByCS |
Indicates the amount of virtual memory utilized by the cell server. |
GB |
|
| totalMemoryUtilByMS |
Indicates the total amount of memory utilized by the management server. |
GB |
|
| cpuUtil |
Indicates the percentage of CPU utilized by the storage cell. |
Percent |
A value close to 100 is a cause of concern.
|
| cpuUtilByCS |
Indicates the percentage of CPU utilized by the cell server. |
Percent |
A high value for this measure indicates that the cell server is consuming too much of CPU resources.
|
| cpuUtilByMS |
Indicates the percentage of CPU utilized by the management server. |
Percent |
A high value for this measure indicates that the management server is consuming too much of CPU resources.
|