eG Monitoring
 

Measures reported by IBMChassFanPckTest

The IBM BladeCenter Chassis comes with four hot-swappable fan modules (fan packs). The fan modules are designed to provide cooling airflow to the chassis and other modules. Each fan module contains two fans. These fan modules ensure that the temperature of the target chassis is within a permissible level. If any of the fan modules are not working properly or become unavailable suddenly, then the temperature of the chassis cannot be automatically regulated. This may cause the internal temperature of the chassis to rise uncontrollably, resulting in considerable damage to the modules in the chassis. This is why, the availability of the fan modules should be verified time and again, and abnormalities (if any) should be escalated to administrators. This is exactly what the Chassis Fanpack test does!

This test auto-discovers the fan modules of the target chassis and reports the availability and current status of each fan module. In addition, the test also checks the number of fans in each fan module and the average speed of the fan modules. This way, it turns the spotlight on those fan modules that are not operating within the permissible range.

Outputs of the test : One set of results for each fan module in the BladeCenter chassis being monitored.

Descriptor of the test : Fan Module

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
packExistense Indicates whether this fan module exists or not.   The values that this measure can report and the numeric values they indicate have been listed in the table below:

Measure Value Numeric Value
Yes 1
No 0

Note:

By default, this measure can report the Measure Values mentioned above indicating whether each fan module exists or not. However, the graph of this measure is indicated using the numeric equivalents.
State Indicates the current status of this fan module.   The values that this measure can report and the numeric values they indicate have been listed in the table below:

Measure Value Numeric Value
Unknown 0
Good 1
Warning 2
Bad 3

Note:

By default, this measure can report the Measure Values mentioned above while indicating the current status of each fan module. However, the graph of this measure is indicated using the numeric equivalents.
ControllerSt Indicates the current status of controller of this fan module.   The values that this measure can report and the numeric values they indicate have been listed in the table below:

Measure Value Numeric Value
Operational 1
Flashing 0
Not present 0
Communication Error 0
Unknown 255

Note:

By default, this measure can report the Measure Values mentioned above while indicating the current status of the controller of each fan module. However, the graph of this measure is indicated using the numeric equivalents.
FanCount Indicates the number of fans in this fan module. Number  
AvgSpeed Indicates the average speed that this fan module can operate. Rpm The value of this measure should be within the permissible range. It is a cause for concern if the permissible range is violated for any reason.