Measures reported by VNXeIOTest

This test auto-discovers the I/O modules on the target storage system and for each I/O module, reports the current health. Using this test, administrators may be alerted to I/O module that failed/degraded and replace those I/O module before irreparable damage occurs to the target storage system.

Outputs of the test : One set of results for each I/O module on the target storage system being monitored.

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
healthStatus Indicates the current health of this I/O module.   The values reported by this measure and its numeric equivalents are mentioned in the table below:

Measure value Numeric Value
Normal 0
Attention 1
Unknown 2
Degraded/Warning 3
Minor failure 4
Major failure 5
Critical failure 6
Non-recoverable error 7

Note:

By default, this measure reports the Measure Values listed in the table above to indicate the current health of this I/O module. The graph of this measure however is represented using the numeric equivalents only - 0 to 7.

The detailed diagnosis of this measure lists the ID, slot, health of the I/O module, model and serial number of the I/O module.