| Measurement |
Description |
Measurement Unit |
Interpretation |
| currHealthState |
Indicates the current health of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Level_1_clear |
0 |
| Level_2_unknown |
1 |
| Level_3_warning |
2 |
| Level_4_minor |
3 |
| Level_5_major |
4 |
| Level_6_critical |
5 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the current health of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 to 5. |
| enableState |
Indicates whether/not this Storage Controller is enabled. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Yes |
0 |
| User_disabled |
1 |
| System_disabled |
2 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate whether/not the Storage Controller is enabled. The graph of this measure however is represented using the numeric equivalents only - 0 to 2. |
| fanHealthState |
Indicates the current health of the fan sensor types (both analog and discrete sensors) of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Level_1_clear |
0 |
| Level_2_unknown |
1 |
| Level_3_warning |
2 |
| Level_4_minor |
3 |
| Level_5_major |
4 |
| Level_6_critical |
5 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the current health of the fan sensor types of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 to 5. |
| fruLifeCycState |
Indicates the current health of the Field Replaceable Units of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Healthy |
0 |
| Initializing |
1 |
| Uninitialized |
2 |
| Failed |
3 |
| Disconnected |
4 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the current state of the IPMI port on this Storage Controller. The graph of this measure however is represented using the numeric equivalents - 0 to 4. |
| iSensorHealthSt |
Indicates the current health state of the temperature/fan/voltage/current/internal sensor types (both analog and discrete sensors) of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Level_1_clear |
0 |
| Level_2_unknown |
1 |
| Level_3_warning |
2 |
| Level_4_minor |
3 |
| Level_5_major |
4 |
| Level_6_critical |
5 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the current health of all the sensor types of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 to 5. |
| iscsiDaemonState |
Indicates the state of the iSCSI deamon of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Healthy |
0 |
| Failed |
1 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the state of the iSCSI deamon of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 or 1. |
| journalState |
Indicates the health of the journals during failover and failback on this Storage controller. |
|
Every piece of information that is not committed to the SSD is kept in multiple locations, called Journals. Each software module has its own Journal, which is not kept on the same Storage Controller, and can be used to restore data in case of unexpected failure. Journals are regarded as highly important and are always kept on Storage Controllers with battery backed up power supplies. In case of a problem with the Battery Backup Unit, the Journal fails over to another Storage Controller. In case of global power failure, the Battery Backup Units ensure that all Journals are written to vault drives in the Storage Controllers and the system is turned off.
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Healthy |
0 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the journal health state regarding failover and failback of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only i.e., 0. |
| lowRamLevel |
Indicates the health of the RAM low level indicator of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Healthy |
0 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the health of the RAM low level indicator of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only i.e., 0. |
| mgmtLinkHealth |
Indicates the current health of the management port of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Level_1_clear |
0 |
| Level_2_unknown |
1 |
| Level_3_warning |
2 |
| Level_4_minor |
3 |
| Level_5_major |
4 |
| Level_6_critical |
5 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the current health of the management port of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 to 5. |
| remoteJournalHealthSt |
Indicates the health of the remote journal of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Healthy |
0 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the health of the remote journal of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only i.e., 0. |
| temperHealthState |
Indicates the health of the temperature sensor types (both analog and discrete sensors) of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Level_1_clear |
0 |
| Level_2_unknown |
1 |
| Level_3_warning |
2 |
| Level_4_minor |
3 |
| Level_5_major |
4 |
| Level_6_critical |
5 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the health of the temperature sensor types of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 to 5. |
| voltageHealthSt |
Indicates the health of the voltage sensor types (both analog and discrete sensors) of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Level_1_clear |
0 |
| Level_2_unknown |
1 |
| Level_3_warning |
2 |
| Level_4_minor |
3 |
| Level_5_major |
4 |
| Level_6_critical |
5 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the health of the voltage sensor types of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 to 5. |
| mgmtPortState |
Indicates the current state of the management port of this Storage Controller. |
|
The values reported by this measure and its numeric equivalents are mentioned in the table below:
| Measure Value |
Numeric Value |
| Up |
0 |
| Down |
1 |
Note:
By default, this measure reports the Measure Values listed in the table above to indicate the current state of the management port of this Storage Controller. The graph of this measure however is represented using the numeric equivalents only - 0 or 1. |