| Measurement |
Description |
Measurement Unit |
Interpretation |
| status |
Indicates the current state of this drive. |
|
The values that this measure can report and their corresponding numeric values have been discussed below:
| Measure Value |
Numeric Value |
| Active |
0 |
| Available |
1 |
| Erasing |
2 |
| Failed |
3 |
| Removing |
4 |
Note:
By default, this measure reports the States listed in the table above to indicate the current state of this drive. The graph of this measure however, represents the same using the numeric equivalents only. |
| activeSessions |
Indicates the number of active iSCSI sessions on this drive. |
Number |
This measure will be available only for metadata drive type. |
| failedDieCount |
Indicates the number of failed hardware elements in this drive. |
Number |
|
| lifeRemainingPercent |
Indicates the percentage of lifetime available in this drive. |
Percentage |
Indicator |
| powerOnHours |
Indicates the number of hours since this drive was powered on. |
Hours |
|
| reallocatedSectors |
Indicates the number of bad sectors that were replaced in this drive. |
Number |
|
| reserveCapacityPercent |
Indicates the percent of data available as reserve on this drive. |
Percentage |
|
| avgLTReadData |
Indicates the average amount of data read for the lifetime from this drive per second during the last measurement period. |
MB/sec |
A consistent decrease in the value of these measures for a drive indicates an I/O processing bottleneck. |
| avgLTWriteData |
Indicates the average amount of data written for the lifetime to this drive per second during the last measurement period. |
MB/sec |
A consistent decrease in the value of these measures for a drive indicates an I/O processing bottleneck. |
| avgReadData |
Indicates the average rate at which data was read from this drive during the last measurement period. |
MB/sec |
A consistent decrease in the value of these measures for a drive indicates an I/O processing bottleneck. |
| avgWriteData |
Indicates the average rate at which data was written to this drive during the last measurement period. |
MB/sec |
A consistent decrease in the value of these measures for a drive indicates an I/O processing bottleneck. |
| totalBandwidth |
Indicates the average rate at which data was read from and written to this drive during the last measurement period. |
MB/sec |
|
| avgReadIOPS |
Indicates the average rate at which read operations were performed on this drive during the last measurement period. |
IOPS |
A consistent decrease in the value of these measures for a drive indicates an I/O processing bottleneck. |
| avgWriteIOPS |
Indicates the average rate at which write operations were performed on this drive during the last measurement period. |
IOPS |
A consistent decrease in the value of these measures for a drive indicates an I/O processing bottleneck. |
| totalIOPS |
Indicates the average rate at which read and write operations were performed on this drive during the last measurement period. |
IOPS |
|
| totalCapacity |
Indicates the total capacity of this drive. |
GB |
|
| usedCapacity |
Indicates the amount of space utilized in this drive. |
GB |
A low value is desired for this measure. |
| freeCapacity |
Indicates the amount of space available for use in this drive. |
GB |
A high value is desired for this measure. |
| usedCapacityPCT |
Indicates the percentage of space utilized in this drive. |
Percent |
A value close to 100 is an indication that the drive is about to run out of space. You may want to consider more drives, in this case, to make more space. |
| freeCapacityPCT |
Indicates the percentage of space available for use in this drive. |
Percent |
A value close to 0 is an indication that the drive is about to run out of space. You may want to consider more drives, in this case, to make more space. |
| usedMemory |
Indicates the amount of memory current used by the node hosting this drive. |
GB |
|