eG Monitoring
 

Measures reported by HwAmperageTest

This test reports the current state, status, and reading for each amperage probe on a server. This test executes only on IBM/Dell servers.

The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
State Indicates the current state of this amperage probe.   The values this measure can report and their numeric equivalents are available in the table below:

Measure Value Numeric Value
Enabled 0
Unknown 1
enabledAndNotReady 3
Not Ready 5

Note:

This measure reports the Measure Values listed in the table above to indicate the current state of an amperage probe. However, in the graph of this measure, the probe state is indicated using only the Numeric Values listed in the above table.

Status Indicates the current status of this amperage probe.   The values this measure can report and their numeric equivalents are available in the table below:

Measure Value Numeric Value
Other 1
Unknown 2
Ok 3
Non Critical Upper 4
Non Critical Lower 5
Non Recoverable Upper 6
Critical Upper 7
Critical Lower 8
Non Recoverable Lower 9
Failed 10

Note:

This measure reports the Measure Values listed in the table above to indicate the current status of an amperage probe. However, in the graph of this measure, the probe status is indicated using only the Numeric Values listed in the above table.

Amperage_probe_reading Indicates the current reading of an amperage probe of type other than amperageProbeTypeIsDiscrete. Amps