| Measurement |
Description |
Measurement
Unit |
Interpretation |
| Operability |
Indicates the operating status of the Fabric Interconnects.
|
|
This measure reports the operating status of the Fabric Interconnects and their numeric equivalents as shown in the table:
| Numeric Value |
State |
| 0 |
Unknown |
| 1 |
Operable |
| 2 |
Inoperable |
Note:By default, this measure reports the above-mentioned States while indicating the operating status of the Fabric Interconnects. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states i.e., 0 to 2.
The detailed diagnosis of this measure provides the Time, Name, PID, Revision, Serial Number and Vendor attributes of each Fabric Interconnects. |
| LoadValue |
Indicates the CPU utilization of the Fabric Interconnects.
|
Percent |
A high value is indicative of excessive CPU usage, and is a cause for concern. |
| AvailMemory |
Indicates the available memory in the Fabric Interconnects.
|
MB |
A low value may indicate a memory bottleneck. |
| CacheMemory |
Indicates the memory allotted for cache (frequently used main memory locations) in the Fabric Interconnects.
|
MB |
|
| TotalMemory |
Indicates the total memory of the Fabric Interconnects.
|
MB |
|
| FanCtrlInlet1 |
Indicates the temperature of fan 1.
|
Celcius |
A low value is desired for this measure. |
| FanCtrlInlet2 |
Indicates the temperature of fan 2.
|
Celcius |
A low value is desired for this measure. |
| FanCtrlInlet3 |
Indicates the temperature of fan 3.
|
Celcius |
A low value is desired for this measure. |
| FanCtrlInlet4 |
Indicates the temperature of fan 4.
|
Celcius |
A low value is desired for this measure. |
| MainboardOutlet1 |
Indicates the temperature of the Fabric Interconnect main board 1.
|
Celcius |
A low value is desired for this measure. |
| MainboardOutlet2 |
Indicates the temperature of the Fabric Interconnect main board 2.
|
Celcius |
A low value is desired for this measure. |
| PsuCtrlInlet1 |
Indicates the temperature of the Fabric Interconnect Power Supply Unit 1.
|
Celcius |
A low value is desired for this measure. |
| PsuCtrlInlet2 |
Indicates the temperature of the Fabric Interconnect Power Supply Unit 2.
|
Celcius |
A low value is desired for this measure. |