| Measurement |
Description |
Measurement
Unit |
Interpretation |
| AdminState |
Indicates the current administrative status of this FC port in this fabric interconnect.
|
|
This measure reports either Enabled or Disabled as the administrative status of an FC port. The states and their corresponding numeric equivalents are shown in the table below:
| Numeric Value |
State |
| 1 |
Enabled |
| 2 |
Disabled |
Note:By default, this measure reports the above-mentioned States while indicating the administrative status of an FC port. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states i.e., 1 or 2. |
| OperState |
Indicates the overall status of this FC port in this fabric interconnect.
|
|
The States reported by this measure and their corresponding numeric equivalents are described in the table below:
| Numeric Value |
State |
| 0 |
Indeterminate |
| 1 |
Up |
| 2 |
Admin-down |
| 3 |
Link-down |
| 4 |
Failed |
| 5 |
No-license |
| 6 |
Link-up |
| 7 |
Hardware-failure |
| 8 |
Software-failure |
| 9 |
Error-disabled |
| 10 |
Sfp-not-present |
Note:By default, this measure reports the above-mentioned States while indicating the overall status of an FC port. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states i.e., 0 to 10.
The detailed diagnosis of this measure provides the Time, ID, Slot ID, Port Type, Network Type, Transport Type, WWPN and Mode attributes for each Fabric Interconnects FC ports. |
| OperSpeed |
Indicates the current operating speed of this FC port in this fabric interconnect.
|
|
The values reported by this measure and their corresponding numeric equivalents are described in the table below:
| Numeric Value |
State |
| 0 |
Indeterminate |
| 1 |
1Gbps |
| 2 |
2Gbps |
| 3 |
4Gbps |
| 4 |
8Gbps |
Note:By default, this measure reports the above-mentioned States while indicating the operating speed of the Fabric Interconnect FC ports. However, the graph of this measure will be represented using the corresponding numeric equivalents of the states i.e., 0 to 4. |
| DataRx |
Indicates the amount of data received by this FC port during the last measurement period. |
MB |
Compare the value of these measures across all FC ports to determine which port is handling the maximum data traffic. |
| DataTx |
Indicates the amount of data sent by this FC port during the last measurement period.
|
MB |
| PacketsRx |
Indicates the number of packets received by this FC port during the last measurement period.
|
Packets |
Compare the value of these measures across all FC ports to determine which port is handling the maximum packet traffic. |
| PacketsTx |
Indicates the number of packets transmitted by this FC port during the last measurement period.
|
Packets |
| CrcRx |
Indicates the number of Cyclic Redundancy Check (CRC) errors that occurred during data trafficking in this FC port, during the last measurement period. |
Errors |
CRC or Cyclic Redundancy Check is a process that helps in identifying any errors that might occur during the data transmission process. Data is usually transmitted in small blocks, and a CRC value is assigned to each block and transmitted along with it. This CRC value is verified at the destination to ensure that it matches the CRC value transmitted from the source. A CRC error occurs when the two values (source and destination) do not match and the test fails. The main benefit of CRC is that it helps you ensure that data you have received or downloaded is not damaged or corrupt.
By comparing the value of this measure across all FC ports, you can accurately identify most error-prone FC port. |
| ErrorRx |
Indicates the total number of errors transmitted by this FC port during the last measurement period. |
Errors |
|
| ErrorTx |
Indicates the total number of errors transmitted through the Fabric Interconnect FC ports during the last measurement period.
|
Errors |
|
| DiscardRx |
Indicates the total amount of data that was discarded during reception of data by this FC port since the last measurement period.
|
Errors |
|
| DiscardTx |
Indicates the total amount of data that was discarded during data transmission through this FC port since the last measurement period.
|
Errors |
|
| TooLongRx |
Indicates the total number of errors that occurred when data of a large size was received by this FC port during the last measurement period. |
Errors |
Ideally, the value of this measure should be low. A high value is indicative of many errors during data reception. To identify the most error-prone port, compare the value of this measure across FC ports. |
| TooShortRx |
Indicates the total number of errors that occurred due to truncated or corrupt data received by this FC port during the last measurement period.
|
Errors |
Ideally, the value of this measure should be low. A high value is indicative of many errors during data transmission. To identify the most error-prone port, compare the value of this measure across FC ports. |
| SignalLosses |
Indicates the signal losses that occurred on this FC port during data transmission and reception in the last measurement period.
|
Errors |
Ideally, the value of this measure should be 0. |
| SynchLosses |
Indicates the losses that occurred due to synchronization of this FC port with other components during the last measurement period.
|
Errors |
Ideally, the value of this measure should be 0. |
| LinkFailures |
Indicates the link failures that occurred between this FC port blade server chassis during the last measurement period. |
Errors |
Ideally, the value of this measure should be 0. |