| Measurement |
Description |
Measurement
Unit |
Interpretation |
| Rack_ps_status |
Indicates the current status of this power supply unit
|
Number |
The table below lists the values that this measure can report, and the states they indicate:
| Value |
State |
| 1 |
noError |
| 2 |
generalFailure |
| 3 |
bistFailure |
| 4 |
fanFailure |
| 5 |
tempFailure |
| 6 |
interlockOpen |
| 7 |
epromFailed |
| 8 |
vrefFailed |
| 9 |
dacFailed |
| 10 |
ramTestFailed |
| 11 |
voltageChannelFailed |
| 12 |
orringdiodeFailed |
| 13 |
brownOut |
| 14 |
giveupOnStartup |
| 15 |
nvramInvalid |
| 16 |
calibrationTableInvalid |
|
| Input_line_status |
Indicates the current status of the input line of this power supply unit
|
Number |
The table below lists the values that this measure can report, and the states they indicate:
| Value |
State |
| 1 |
noError |
| 2 |
lineOverVoltage |
| 3 |
LineUnderVoltage |
| 4 |
lineHit |
| 5 |
brownOut |
| 6 |
linePowerLoss |
|
| Max_power |
Indicates the maximum power output of this power supply unit
|
Watts |
  |
| Curr_power |
Indicates the current power output of this power supply unit
|
Watts |
By comparing the value of this measure across power supply units, you can quickly identify the unit that is producing the maximum power output currently, and the rack blade with which it is associated. |
| Power_supply_present_st |
Indicates the availability of this power supply unit
|
Number |
The table below lists the values that this measure can report, and the states they indicate:
| Value |
State |
| 1 |
Other |
| 2 |
Absent |
| 3 |
Present |
|
| Power_supply_condition |
Indicates the current condition of this power supply unit
|
Number |
The table below lists the values that this measure can report, and the states they indicate:
| Value |
State |
Description |
| 1 |
Other |
The status could not be determined or not present |
| 2 |
OK |
The power supply is operating normally |
| 3 |
Degraded |
A temperature sensor, fan or other power supply component is outside of normal operating range |
| 4 |
Failed |
A power supply component detects a condition that could possibly damage the system |
|