eG Monitoring
 
Measures reported by EventLogTest

This test reports the statistical information about the events generated by various applications, windows services, and drivers in the target system.

Measurement Description Measurement Unit Interpretation
App_error_count This refers to the number of application error events that were generated.  Number A very low value (zero) indicates that the system is in a healthy state and all applications are running smoothly without any potential problems.

An increasing trend or high value indicates the existence of problems like loss of functionality or  data in one or more applications.  

Please check the Application Logs in the Event Log Viewer for more details.

App_infrm_count This refers to the number of application information events generated when the test was last executed. Number A change in the value of this measure may indicate infrequent but successful operations performed by one or more applications.

Please check the Application Logs in the Event Log Viewer for more details.

App_warning_count This refers to the number of warnings that were generated when the test was last executed. Number A high value of this measure indicates application problems that may not have an immediate impact, but may cause future problems in one or more applications.

Please check the Application Logs in the Event Log Viewer for more details.

Sys_error_count This refers to the number of system error events generated during the last execution of the test. Number A very low value (zero) indicates that the system is in healthy state and all Windows services and low level drivers are running without any potential problems.

An increasing trend or a high value indicates the existence of problems such as loss of functionality or  data in one or more Windows services and low level drivers.  

Please check the System Logs in the Event Log Viewer for more details.

Sys_infrm_count This refers to the number of service-related and driver-related information events that were generated during the test's last execution. Number A change in value of this measure may indicate infrequent but successful operations performed by one or more applications.

Please check the System Logs in the Event Log Viewer for more details.

Sys_warning_count This refers to the number of service-related and driver-related warnings generated during the test's last execution. Number A high value of this measure indicates problems that may not have an immediate impact, but may cause future problems in one or more Windows servers and low level drivers.

Please check the System Logs in the Event Log Viewer for more details.

App_critical_count This refers to the number of critical events that were generated when the test was last executed. Number A critical event is one that an application or a component cannot automatically recover from.

This measure is applicable only for Windows 2008/Windows Vista/Windows 7 systems.

A very low value (zero) indicates that the system is in a healthy state and all applications are running smoothly without any potential problems.

An increasing trend or high value indicates the existence of fatal/irrepairable problems in one or more applications.

The detailed diagnosis of this measure describes all the critical application events that were generated during the last measurement period.

Please check the Application Logs in the Event Log Viewer for more details.

App_verbose_count Indicates the number of verbose events that were generated when the test was last executed. Number Verbose logging provides more details in the log entry, which will enable you to troubleshoot issues better.

This measure is applicable only for Windows 2008/Windows Vista/Windows 7 systems.

The detailed diagnosis of this measure describes all the verbose events that were generated during the last measurement period.

Please check the Application Logs in the Event Log Viewer for more details.

Sys_verbose_count This refers to the number of system verbose events that were generated during the last execution of the test. Number Verbose logging provides more details in the log entry, which will enable you to troubleshoot issues better.

This measure is applicable only for Windows 2008/Windows Vista/Windows 7 systems.

The detailed diagnosis of this measure describes all the verbose events that were generated during the last measurement period.

Please check the System Logs in the Event Log Viewer for more details.

Sys_critical_count Indicates the number of critical events that were generated when the test was last executed. Number A critical event is one that a system cannot automatically recover from.

This measure is applicable only for Windows 2008/Windows Vista/Windows 7 systems.

A very low value (zero) indicates that the system is in a healthy state and is running smoothly without any potential problems.

An increasing trend or high value indicates the existence of fatal/irrepairable problems in the system.

The detailed diagnosis of this measure describes all the critical system events that were generated during the last measurement period.

Please check the System Logs in the Event Log Viewer for more details.