eG Monitoring
 

Measures reported by HitachiPortTest

This test is used to assess the load on every enabled port on the storage device using the HitachiPort test.

 The measures made by this test are as follows:

Measurement Description Measurement Unit Interpretation
IO_Rate Indicates the number of I/O operations performed on this port per second. IOPS If this measure reports a high value or if the value of the measure increases consistently, it is indicative of unusually high I/O activity on this port. Comparing the value of this measure across ports can accurately indicate which port is currently experiencing heavy workloads. Observing the variations in this measure over a period of time will enable you to figure out bottlenecks in load balancing.
Read_Rate Indicates the number of read operations performed on this port per second. IOPS  
Write_Rate Indicates the number of write commands issued on this port per second. IOPS  
Read_Hit Indicates the percentage of read requests that were served from the cache. % Ideally, the value of this measure should be high. A low value is a cause for concern, as it indicates that a majority of the read requests have been serviced by direct disk accesses, which in turn would increase the processing overheads.
Write_Hit Indicates the percentage of write requests that were served from the cache. % Ideally, the value of this measure should be high. A low value is a cause for concern, as it indicates that a majority of the write requests have been serviced by direct disk accesses, which in turn would increase the processing overheads.
Trans_Rate Indicates the transfer size of read/write commands per second. KB/sec  
Read_Trans_Rate Indicates the transfer size of read commands per second. KB/sec  
Write_Trans_Rate Indicates the transfer size of write commands per second. KB/sec