Agents Administration - Tests
 

Configuration of VNXeFibreTest

For every port configured on each of the storage processors (A and B) supported by the target storage system, this test reports the health of the ports, the I/O load on the ports and the processing ability of the ports. In the process, the test not only points administrators to overloaded ports, but also puts a finger on ports that are slow when processing I/O requests.

The default parameters associated with this test are as follows:

  • The TEST PERIOD list box helps the user to decide how often this test needs to be executed.

  • In the HOST text box, specify the IP address of the storage system for which this test is to be configured.

  • The eG agent uses the command-line utility, UEMCli.exe, which is part of the UniSphere Management Suite, to communicate with and monitor the storage device. To enable the eG agent to invoke the CLI, configure the full path to the CLI in the UNISPHERE CLI PATH text box.

  • Provide the credentials of a user possessing monitor role to access the storage device in the USERNAME and PASSWORD text boxes.

  • Confirm the password by retyping it in CONFIRM PASSWORD text box.

  • Specify the duration (in seconds) beyond which this test should time out in the TIMEOUT text box. The default is 300 seconds.

  • To make diagnosis more efficient and accurate, eG embeds an optional detailed diagnostic capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test, by default, for a particular server, choose the On option against DETAILED DIAGNOSIS. To disable the capability, click on the Off option.

    The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:

    • The eG manager license should allow the detailed diagnosis capability.

    • Both the bad and normal frequencies configured for the detailed diagnosis measures should not be 0.

  • If multiple components of the same component type are awaiting configuration, then an APPLY TO OTHER COMPONENTS check box will appear in this page. Clicking on this check box will allow you to apply the configuration to all/selected components of that type.

  • Once the necessary values have been provided, clicking on the UPDATE button will register the changes made.

When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of “none” in the parameter value indicates that the corresponding parameter value can be changed if required.