Agents Administration - Tests
 

Default Parameters for MariaEvtStmtTest

This test monitors the performance schema tables of the target Maria Database server and reports the number of digest statements executing on the database server. This test also throws light on the SQL statements that are running on the performance schema tables, the statements waiting for locks and the rows affected and examined. Using this test, administrators can also figure out the FLUSH commands executed on the tables as well as the temporary tables.

This page depicts the default parameters that need to be configured for the MariaEvtStmtTest test.

  • The TEST PERIOD list box helps the user to decide how often this test needs to be executed.

  • Specify the name of the database that is to be monitored on the target Maria Database server in the DATABASE text box.

  • The eG agent has to be configured with the credentials of a user who has server-wide PROCESS and SELECT privileges on the monitored Maria Database server. To know how to create such a user, click here.

  • Confirm the password by retyping it in the CONFIRM PASSWORD text box.

  • The DD FREQUENCY refers to the frequency with which detailed diagnosis measures are to be generated for this test. The default is 1:1. This indicates that, by default, detailed measures will be generated every time this test runs, and also every time the test detects a problem. You can modify this frequency, if you so desire. Also, if you intend to disable the detailed diagnosis capability for this test, you can do so by specifying none against DD FREQUENCY.

  • Once the above values are provided, click on the UPDATE button to register the changes made.

When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of “none” in the parameter value indicates that the corresponding parameter value can be changed if required.