|
Default Parameters for VnxSpPortTest
For every port configured on each of the storage processors (A and B) supported by the VNX storage system, this test reports the port state, the I/O load on the ports, the processing ability of the ports, and the SFP state. In the process, the test not only points administrators to overloaded ports, but also puts a finger on ports that are slow when processing I/O requests.
This page depicts the default parameters that need to be configured for the VnxSpPortTest
-
The eG agent uses the command-line utility, NaviSecCli.exe, which is part of the NaviSphere Management Suite, to communicate with and monitor the block-only storage in the EMC VNX Unified storage system. To enable the eG agent to invoke this CLI, configure the full path to the CLI in the NAVISECCLIPATH text box.
-
In the TIMEOUT text box, indicate the duration (in seconds) for which this test should wait for a response from the storage device. By default, this is set to 120 seconds. Note that the TIMEOUT duration should always range between 3 and 600 only.
To use the NaviSphere CLI, the eG agent needs to be configured with a user scope. Scope defines the access radius of the user account (USER and PASSWORD) that you have configured for this test. Set USER SCOPE to Local if the user account you have configured for this test applies to the monitored storage system only. Set USER SCOPE to Global if the user account you have configured applies to all the storage systems within a domain.
By default, the ADDITIONAL CONTROLLER IP text box is set to none. This implies that by default, the storage device being monitored supports a single controller/storage processor only. Sometimes, a storage device could be configured with two controllers i.e., say for e.g., storage processor A and storage processor B, so as to provide fail-over services - in other words, if the storage processor A is down, then the storage processor B will take over to provide the critical storage services. In this case, you can provide the alternate controller IP i.e., the IP address of the storage processor B in the ADDITIONAL CONTROLLER IP text box.
When changing default configurations of tests, the values with “$” indicate variables that will be replaced by the eG system according to the specific server being managed - for instance, $hostName is the host/nickname of the target host, $port is the port number of the server being monitored. E.g., for a server xyz:80, $hostName will be changed automatically by the eG manager to “xyz” and $port will be changed to “80” when configuring a test.
|