Agents Administration - Tests
 

Default Parameters for TibEMSServerTest

This test is used to provide the overall information about the server.

This test provides information such as server status, number of queues, number of topics, and the number of queues and topics that are administered by the server, queues and topics that are created automatically by the server and the queues and topics that are created on-the-fly by applications.

By executing show config or show server command, the static and dynamic information of topics and as well as queues can be obtained.

The default parameters associated with this test are as follows:

  • The TEST PERIOD list box helps the user to decide how often this test needs to be executed. 

  • Prior to monitoring the Tibco EMS server, you will have to build a .bat or .sh file (depending upon the operating system on which Tibco EMS is functioning) bundled with the commands that the eG agent needs to execute on the Tibco EMS server for collecting the required metrics. The commands to be invoked by the the .bat or .sh file are as follows:

    tcp://{IPAddressorHostName_of_TibcoEMS}:{PortNumber_of_TibcoEMS} show server

    tcp://{IPAddressorHostName_of_TibcoEMS}:{PortNumber_of_TibcoEMS} show durables

    tcp://{IPAddressorHostName_of_TibcoEMS}:{PortNumber_of_TibcoEMS} show queues

    tcp://{IPAddressorHostName_of_TibcoEMS}:{PortNumber_of_TibcoEMS} show topics

    tcp://{IPAddressorHostName_of_TibcoEMS}:{PortNumber_of_TibcoEMS} show connections

    For instance, if the IP address of your Tibco EMS server is 192.168.10.28 and its port is say, 9090, then a sample command in the .bat or .sh file would be:

    tcp://192.168.10.28:9090 show server

    The .bat/.sh file so created can be saved to any location on the Tibco EMS host. Then, while configuring this test, make sure you provide the full path to this .bat or .sh file in the COMMANDPATH text box so that, the agent can execute the file, invoke the commands bundled into it, and extract the desired metrics from the server.

  • Once the above value is provided, click on the Update button to register the changes made.