Configuration
of SybStmtStatsTest
This test reports critical resource usage and general performance statistics related to transactions that are executed on the Sybase server. The default parameters associated with
this test are as follows:
-
The TEST PERIOD
list box helps the user to decide how often this test needs to be
executed.
-
In the HOST
text box, the host name of the server for which the test is to be
configured has to be specified.
-
The port number to
which the selected server is listening to has to be mentioned in the PORT
text box.
-
To enable this test to connect to the Sybase server and collect the required metrics, it is enough if you configure the test with the name of a Sybase user who has the “mon_role” credential in the USER text box. However, for best results, it is recommended that you configure all Sybase tests with the credentials of a Sybase user who has the “mon_role”, “sa_role”, and “sybase_ts_role”.
-
The
password corresponding to the above user has to be entered in the PASSWORD
text box.
-
Confirm
the password by retyping it in the CONFIRM PASSWORD text
box.
-
Specify the number of long running queries for which details will be available in the detailed diagnosis page. By default, this parameter is set to 5. This indicates that even if the total number of long running queries is, say 10, the detailed diagnosis of this test will provide information pertaining to only 5 queries by default. For information related to more number of queries, you should increase the DDROWCOUNT.
-
To make diagnosis more efficient and accurate, the eG Enterprise suite embeds an optional DETAILED DIAGNOSIS capability. With this capability, the eG agents can be configured to run detailed, more elaborate tests as and when specific problems are detected. To enable the detailed diagnosis capability of this test for a particular server, choose the ON option. To disable the capability, click on the OFF option.
The option to selectively enable/disable the detailed diagnosis capability will be available only if the following conditions are fulfilled:
- The eG manager license should allow the detailed diagnosis capability.
- Both the normal and abnormal frequencies configured for the detailed diagnosis measures should not be 0.
-
If multiple components of the same component type are awaiting configuration, then an APPLY TO OTHER COMPONENTS check box will appear in this page. Clicking on this check box will allow you to apply the configuration to all/selected components of that type.
-
Once the necessary
values have been provided, clicking on the UPDATE button will
register the changes made.
When changing the
configuration for specific servers, a “*” beside the text box
corresponding to the parameter signifies that these values have to be
manually configured by the user. The parameter values that require to
be configured will typically be prefixed with a “$” or contain a
series of “*”. A value of "none"
in the parameter value indicates that the corresponding parameter
value can be changed if required.
|