Configuration of EMCPvMeHstPrtTest
A Host Port is a port on a controller module that interfaces with a host computer, either directly or through a network switch. Since host ports facilitate host-controller interactions, any slowdown in I/O processing that a user may complain of can be attributed to an overloaded port or poor I/O performance of a port. To be able to proactively detect such problems with a port and take adequate measures to curb them, administrators need to keep an eye on the level of I/O activity on each host port, measure the I/O processing ability of the ports, and identify the ‘weak links‘ of the storage environment - i.e., isolate those host ports that are either overloaded or are slow in processing requests. Such host ports can be identified using the EMCPvMeHstPrtTest. For every host port on a controller, this test reports the rate at which the port services read and write requests and reveals the count of requests that are pending processing by the port. This way, the test clearly points administrators to a probable overload or a processing delay with the host ports.
The default parameters associated with this test are:
In the HOST text box, specify the HOST for which this test is to be configured. Since the storage device is managed using the IP address of its storage controller, the same will be displayed as host. In case of a dual-controller configuration, the IP address of the primary controller will be displayed here.
By default, this test always connects to the Host to collect metrics. If the Host is unavailable, then the test will not be able to execute. This is because, the Additional Controller IP is set to none by default.
If the monitored storage device has two controllers, then you can configure the test to connect to an alternate controller, if the host is unreachable. For this purpose, specify the IP address of the alternate controller in the Additional Controller IP text box.
In order to monitor a EMC PowerVault ME storage system, the eG agent has to be configured with the credentials of a user who has been assigned the Monitor role. Specify the login credentials of such a user in the USER and PASSWORD text boxes. To know how to create such a user, refer to Pre-requisites-for-monitoring-the-EMC PowerVault-ME-storage-system. Confirm the password by retyping it in CONFIRM PASSWORD text box.
The Management Controller of the EMC PowerVault ME storage system provides access for monitoring and management via the HTTP and HTTPS protocols for XML API request/response semantics. To enable the eG agent to access the management controller, invoke the XML API commands, and collect the required metrics, you need to specify the SERVICE PORT on the controller that listens for HTTP/HTTPS requests for XML API semantics. By default, this is port 80.
By default, EMC PowerVault ME system is not SSL-enabled. This is why, SSL flag is set to False by default. If it is SSL-enabled, then change this flag to True.
When changing the configuration for specific servers, a “*” beside the text box corresponding to the parameter signifies that these values have to be manually configured by the user. The parameter values that require to be configured will typically be prefixed with a “$” or contain a series of “*”. A value of “none” in the parameter value indicates that the corresponding parameter value can be changed if required.
|